This case report describes an alternative minimally invasive treatment option using 4-mm-long ultrashort implants placed to rehabilitate a severely atrophic edentulous maxilla. The patient, coming from a full removable denture, asked for an implant prosthesis avoiding reconstructive surgeries and expensive procedures. Considering that the mean available bone was about 4.8 mm in height on Cone Beam Computed Tomography (CBCT) scans, 6 implants were placed where bone volumes were sufficient to receive 4-mm-ultrashort implants. Six months after implant placement an implant-supported bar-retained overdenture prosthesis was delivered. The healing process was uneventful and 1 year after loading the result appears clinically and radiographically stable and the patient is fully satisfied. The described approach, despite some prosthetic compromises, within all the limitations of this case report, might be applied in selected cases, reducing rehabilitative times, possible complications and costs. However, longer follow-ups on large number of patients coming from Randomised Controlled clinical Trials (RCTs) are necessary before making more reliable recommendations.
Minimally invasive rehabilitation of a severely atrophic and fully edentulous maxilla using 4-mm-ultrashort implants: A case report with 1-year follow-up / Felice, P.; Karaban, M.; Pistilli, R.; Bellini, P.; Bonifazi, L.; Barausse, C.. - In: ORAL AND MAXILLOFACIAL SURGERY CASES. - ISSN 2214-5419. - 6:3(2020), pp. 100176-100183. [10.1016/j.omsc.2020.100176]
Minimally invasive rehabilitation of a severely atrophic and fully edentulous maxilla using 4-mm-ultrashort implants: A case report with 1-year follow-up
Bellini P.;
2020
Abstract
This case report describes an alternative minimally invasive treatment option using 4-mm-long ultrashort implants placed to rehabilitate a severely atrophic edentulous maxilla. The patient, coming from a full removable denture, asked for an implant prosthesis avoiding reconstructive surgeries and expensive procedures. Considering that the mean available bone was about 4.8 mm in height on Cone Beam Computed Tomography (CBCT) scans, 6 implants were placed where bone volumes were sufficient to receive 4-mm-ultrashort implants. Six months after implant placement an implant-supported bar-retained overdenture prosthesis was delivered. The healing process was uneventful and 1 year after loading the result appears clinically and radiographically stable and the patient is fully satisfied. The described approach, despite some prosthetic compromises, within all the limitations of this case report, might be applied in selected cases, reducing rehabilitative times, possible complications and costs. However, longer follow-ups on large number of patients coming from Randomised Controlled clinical Trials (RCTs) are necessary before making more reliable recommendations.| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S2214541920300377-main.pdf
Open access
Descrizione: articolo principale
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
5.51 MB
Formato
Adobe PDF
|
5.51 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate

I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris




