Low-cost, minimally invasive sensors able to provide real-time monitoring of wound infection can enable the optimization of healthcare resources in chronic wounds management. Here, a novel printed organic electrochemical transistors (OECT) biosensor for monitoring uric acid (UA), a bacterial infection biomarker in wounds, is demonstrated in artificial wound exudate. The sensor exploits the enzymatic conversion of UA to 5-hydroxyisourate, catalyzed by Uricase entrapped in a dual-ionic-layer hydrogel membrane casted onto the gate. The sensor response is based on the catalytic oxidation of the hydrogen peroxide, generated as part of the Uricase regeneration process, at the Pt modified gate. The proposed dual membrane avoids the occurrence of nonspecific faradic reactions as, for example, the direct oxidation of UA or other electroactive molecules that would introduce a potentially false negative response. The biosensor is robust and its response is reproducible both in phosphate buffer saline and in complex solutions mimicking the wound exudate. The sensor has a high sensitivity in the range encompassing the pathological levels of UA in wounds (<200 μm) exhibiting a limit of detection of 4.5 μm in artificial wound exudate. All these characteristics make this OECT-based biosensor attractive for wound monitoring interfaced to the patient.

Flexible Printed Organic Electrochemical Transistors for the Detection of Uric Acid in Artificial Wound Exudate / Galliani, M.; Diacci, C.; Berto, M.; Sensi, M.; Beni, V.; Berggren, M.; Borsari, M.; Simon, D. T.; Biscarini, F.; Bortolotti, C. A.. - In: ADVANCED MATERIALS INTERFACES. - ISSN 2196-7350. - 7:23(2020), pp. 2001218-2001225. [10.1002/admi.202001218]

Flexible Printed Organic Electrochemical Transistors for the Detection of Uric Acid in Artificial Wound Exudate

Galliani M.;Berto M.;Sensi M.;Borsari M.;Biscarini F.;Bortolotti C. A.
2020

Abstract

Low-cost, minimally invasive sensors able to provide real-time monitoring of wound infection can enable the optimization of healthcare resources in chronic wounds management. Here, a novel printed organic electrochemical transistors (OECT) biosensor for monitoring uric acid (UA), a bacterial infection biomarker in wounds, is demonstrated in artificial wound exudate. The sensor exploits the enzymatic conversion of UA to 5-hydroxyisourate, catalyzed by Uricase entrapped in a dual-ionic-layer hydrogel membrane casted onto the gate. The sensor response is based on the catalytic oxidation of the hydrogen peroxide, generated as part of the Uricase regeneration process, at the Pt modified gate. The proposed dual membrane avoids the occurrence of nonspecific faradic reactions as, for example, the direct oxidation of UA or other electroactive molecules that would introduce a potentially false negative response. The biosensor is robust and its response is reproducible both in phosphate buffer saline and in complex solutions mimicking the wound exudate. The sensor has a high sensitivity in the range encompassing the pathological levels of UA in wounds (<200 μm) exhibiting a limit of detection of 4.5 μm in artificial wound exudate. All these characteristics make this OECT-based biosensor attractive for wound monitoring interfaced to the patient.
2020
7
23
2001218
2001225
Flexible Printed Organic Electrochemical Transistors for the Detection of Uric Acid in Artificial Wound Exudate / Galliani, M.; Diacci, C.; Berto, M.; Sensi, M.; Beni, V.; Berggren, M.; Borsari, M.; Simon, D. T.; Biscarini, F.; Bortolotti, C. A.. - In: ADVANCED MATERIALS INTERFACES. - ISSN 2196-7350. - 7:23(2020), pp. 2001218-2001225. [10.1002/admi.202001218]
Galliani, M.; Diacci, C.; Berto, M.; Sensi, M.; Beni, V.; Berggren, M.; Borsari, M.; Simon, D. T.; Biscarini, F.; Bortolotti, C. A.
File in questo prodotto:
File Dimensione Formato  
Galliani_Adv.Mater.Interf_2020.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 904 kB
Formato Adobe PDF
904 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1212467
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 50
social impact