Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
The main goal of the NA62 experiment at the CERN SPS accelerator is to measure the branching fraction of the ultra-rare decay K+ → π+vv¯ with 10% accuracy. Key aspects of the detector configuration are described, with emphasis on tagging and timestamping the minority kaons in the high intensity, unseparated, charged-particle beam using KTAG, an upgraded version of a CEDAR differential Cherenkov detector. Data are presented showing that KTAG was successfully commissioned at CERN in November 2012.
The kaon identification system in the NA62 experiment at CERN SPS / Rinella, G.A., Ambrosino, F., Angelucci, B., Antonelli, A., Anzivino, G., Arcidiacono, R., Azhinenko, I., Balev, S., Bendotti, J., Biagioni, A., Biino, C., Bizzeti, A., Blazek, T., Blik, A., Bloch-Devaux, B., Bolotov, V., Bonaiuto, V., Britton, D., Britvich, G., Brook, N., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 9:12(2014), pp. C12048-C12048. [10.1088/1748-0221/9/12/C12048]
The kaon identification system in the NA62 experiment at CERN SPS
The main goal of the NA62 experiment at the CERN SPS accelerator is to measure the branching fraction of the ultra-rare decay K+ → π+vv¯ with 10% accuracy. Key aspects of the detector configuration are described, with emphasis on tagging and timestamping the minority kaons in the high intensity, unseparated, charged-particle beam using KTAG, an upgraded version of a CEDAR differential Cherenkov detector. Data are presented showing that KTAG was successfully commissioned at CERN in November 2012.
The kaon identification system in the NA62 experiment at CERN SPS / Rinella, G.A., Ambrosino, F., Angelucci, B., Antonelli, A., Anzivino, G., Arcidiacono, R., Azhinenko, I., Balev, S., Bendotti, J., Biagioni, A., Biino, C., Bizzeti, A., Blazek, T., Blik, A., Bloch-Devaux, B., Bolotov, V., Bonaiuto, V., Britton, D., Britvich, G., Brook, N., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 9:12(2014), pp. C12048-C12048. [10.1088/1748-0221/9/12/C12048]
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1209515
Citazioni
ND
0
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. L’Università di Modena e Reggio Emilia non si assume alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione.