The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at s = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirements. © 2012 IOP Publishing Ltd and Sissa Medialab srl.
Performance of the LHCb muon system / Alves, Jr. A. A.; Anderlini, L.; Anelli, M.; Nobrega, R. A.; Auriemma, G.; Baldini, W.; Bencivenni, G.; Berutti, R.; Bizzeti, A.; Bocci, V.; Bondar, N.; Bonivento, W.; Botchin, B.; Cadeddu, S.; Campana, P.; Carboni, G.; Cardini, A.; Carletti, M.; Ciambrone, P.; Dane, E.; De Capua, S.; De Leo, V.; Deplano, C.; De Simone, P.; Dettori, F.; Falabella, A.; Rodriguez, F. F.; Frosini, M.; Furcas, S.; Furfaro, E.; Graziani, G.; Gruber, L.; Haefeli, G.; Kashchuk, A.; Iacoangeli, F.; Lai, A.; Lanfranchi, G.; Lenzi, M.; Levitskaya, O.; Mair, K.; Maev, O.; Manca, G.; Mara, M.; Martellotti, G.; Rodrigues, A. M.; Messi, R.; Murtas, F.; Neustroev, P.; Oldeman, R. G. C.; Palutan, M.; Passaleva, G.; Penso, G.; Pinci, D.; Polycarpo, E.; Raspino, D.; Sabatino, G.; Saitta, B.; Salamon, A.; Santacesaria, R.; Santovetti, E.; Saputi, A.; Sarti, A.; Satriano, C.; Satta, A.; Savrie, M.; Schmidt, B.; Schneider, T.; Sciascia, B.; Sciubba, A.; Serra, N.; Shatalov, P.; Vecchi, S.; Veltri, M.; Volkov, S.; Vorobyev, A.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 8:2(2013), pp. P02022-P02022. [10.1088/1748-0221/8/02/P02022]
Performance of the LHCb muon system
Bizzeti A.;
2013
Abstract
The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at s = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirements. © 2012 IOP Publishing Ltd and Sissa Medialab srl.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris