Objectives/Hypothesis: To assess hearing outcomes and complications of endoscopic stapes surgery by a single surgeon in a 10-year period, to compare these data with conventional microscopic procedures by the same operator, and to describe the learning curve of endoscopic stapedotomy. Study Design: Retrospective study. Methods: This is a retrospective study on patients who underwent endoscopic stapes surgery performed by the same senior surgeon, experienced both in microscopic and endoscopic techniques, between January 2009 and December 2018. Audiological data were compared, and intraoperative and postoperative complications were collected. The surgeon's last 30 cases of microscopic stapedotomy were enrolled as the control group. The results of the first 100 endoscopic stapes surgeries were analyzed separately to create a cumulative sum (CUSUM) control chart for learning curve assessment. Results: One hundred seventy-eight endoscopic and 30 microscopic stapes surgeries were included. In the endoscopic group, the mean postoperative air–bone gap was 8.2 dB. No significant differences between the endoscopic and microscopic preoperative and postoperative values were reported. A total of eight complications (4.5%) were observed in the endoscopic cohort, although in the control group, no complication occurred. The mean surgical time was 51.9 minutes in the endoscopic group versus 48.2 minutes in the microscopic group (P >.05). No association between stapedotomy success and the increasing number of procedures was found. Conclusions: Our article demonstrates that functional results from endoscopic stapes surgery are similar to those from microscopic stapes surgery in terms of both safety and efficacy. After gaining endoscopic experience, the surgical duration of stapes surgery will be adequate starting from the first cases. Level of Evidence: 4 Laryngoscope, 2020.

Functional Results and Learning Curve of Endoscopic Stapes Surgery: A 10-Year Experience / Lucidi, D.; Molinari, G.; Reale, M.; Alicandri Ciufelli, M.; Presutti, L.. - In: LARYNGOSCOPE. - ISSN 0023-852X. - 131:4(2021), pp. 885-891. [10.1002/lary.28943]

Functional Results and Learning Curve of Endoscopic Stapes Surgery: A 10-Year Experience

Molinari G.;Alicandri Ciufelli M.;Presutti L.
2021

Abstract

Objectives/Hypothesis: To assess hearing outcomes and complications of endoscopic stapes surgery by a single surgeon in a 10-year period, to compare these data with conventional microscopic procedures by the same operator, and to describe the learning curve of endoscopic stapedotomy. Study Design: Retrospective study. Methods: This is a retrospective study on patients who underwent endoscopic stapes surgery performed by the same senior surgeon, experienced both in microscopic and endoscopic techniques, between January 2009 and December 2018. Audiological data were compared, and intraoperative and postoperative complications were collected. The surgeon's last 30 cases of microscopic stapedotomy were enrolled as the control group. The results of the first 100 endoscopic stapes surgeries were analyzed separately to create a cumulative sum (CUSUM) control chart for learning curve assessment. Results: One hundred seventy-eight endoscopic and 30 microscopic stapes surgeries were included. In the endoscopic group, the mean postoperative air–bone gap was 8.2 dB. No significant differences between the endoscopic and microscopic preoperative and postoperative values were reported. A total of eight complications (4.5%) were observed in the endoscopic cohort, although in the control group, no complication occurred. The mean surgical time was 51.9 minutes in the endoscopic group versus 48.2 minutes in the microscopic group (P >.05). No association between stapedotomy success and the increasing number of procedures was found. Conclusions: Our article demonstrates that functional results from endoscopic stapes surgery are similar to those from microscopic stapes surgery in terms of both safety and efficacy. After gaining endoscopic experience, the surgical duration of stapes surgery will be adequate starting from the first cases. Level of Evidence: 4 Laryngoscope, 2020.
2021
131
4
885
891
Functional Results and Learning Curve of Endoscopic Stapes Surgery: A 10-Year Experience / Lucidi, D.; Molinari, G.; Reale, M.; Alicandri Ciufelli, M.; Presutti, L.. - In: LARYNGOSCOPE. - ISSN 0023-852X. - 131:4(2021), pp. 885-891. [10.1002/lary.28943]
Lucidi, D.; Molinari, G.; Reale, M.; Alicandri Ciufelli, M.; Presutti, L.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1208623
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact