PURPOSE: To evaluate visual performance and wavefront error after multifocal intraocular lens (MIOL) implant with or without capsular tension ring (CTR). METHODS: Sixty eyes of 60 candidates for phacoemulsification and MIOL implantation were included in the study and were randomly divided into 2 groups. Thirty eyes (group 1) were implanted with the AcrySof ReSTOR® SN60D3 MIOL and Corneal® ACPI 11 CTR and 30 eyes (group 2) received the same MIOL with no CTR. RESULTS: Twenty days and at 360 days after surgery, the uncorrected and corrected distance visual acuity at high and low contrast were not significantly different between the 2 groups. The root mean square (RMS) of ocular and internal wavefront error was significantly different in the 2 groups early after surgery and did not modify significantly over the 1-year follow-up period. The RMS of total and internal high-order aberrations and ocular and internal trefoil and coma aberrations were significantly lower in group 1 compared to group 2 (p<0.05). Ocular, corneal, internal modulation transfer function at high and low spatial frequencies and ocular, corneal, internal Strehl ratio were not significantly different between the groups. The IOL decentration and tilt were higher in group 1 compared to group 2. CONCLUSION: ReSTOR MIOL was effective in improving visual performance and provided a good quality of vision due to a significant reduction of high-order spherical aberration. The implant of CTR additionally reduced the ocular wavefront error related to a reduction of third-order aberration related to better IOL position.

Multifocal IOL implant with or without capsular tension ring: study of wavefront error and visual performance / Mastropasqua, R; Toto, L; Vecchiarino, L; Falconio, G; Nicola, Md; Mastropasqua, A. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 23:4(2013), pp. 510-517. [10.5301/ejo.5000258]

Multifocal IOL implant with or without capsular tension ring: study of wavefront error and visual performance

Mastropasqua R;
2013

Abstract

PURPOSE: To evaluate visual performance and wavefront error after multifocal intraocular lens (MIOL) implant with or without capsular tension ring (CTR). METHODS: Sixty eyes of 60 candidates for phacoemulsification and MIOL implantation were included in the study and were randomly divided into 2 groups. Thirty eyes (group 1) were implanted with the AcrySof ReSTOR® SN60D3 MIOL and Corneal® ACPI 11 CTR and 30 eyes (group 2) received the same MIOL with no CTR. RESULTS: Twenty days and at 360 days after surgery, the uncorrected and corrected distance visual acuity at high and low contrast were not significantly different between the 2 groups. The root mean square (RMS) of ocular and internal wavefront error was significantly different in the 2 groups early after surgery and did not modify significantly over the 1-year follow-up period. The RMS of total and internal high-order aberrations and ocular and internal trefoil and coma aberrations were significantly lower in group 1 compared to group 2 (p<0.05). Ocular, corneal, internal modulation transfer function at high and low spatial frequencies and ocular, corneal, internal Strehl ratio were not significantly different between the groups. The IOL decentration and tilt were higher in group 1 compared to group 2. CONCLUSION: ReSTOR MIOL was effective in improving visual performance and provided a good quality of vision due to a significant reduction of high-order spherical aberration. The implant of CTR additionally reduced the ocular wavefront error related to a reduction of third-order aberration related to better IOL position.
2013
23
4
510
517
Multifocal IOL implant with or without capsular tension ring: study of wavefront error and visual performance / Mastropasqua, R; Toto, L; Vecchiarino, L; Falconio, G; Nicola, Md; Mastropasqua, A. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 23:4(2013), pp. 510-517. [10.5301/ejo.5000258]
Mastropasqua, R; Toto, L; Vecchiarino, L; Falconio, G; Nicola, Md; Mastropasqua, A
File in questo prodotto:
File Dimensione Formato  
17.pdf

Accesso riservato

Dimensione 192.43 kB
Formato Adobe PDF
192.43 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1201158
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact