Aim: the aim of this in vitro study was to test whether the implant placement accuracy and the operating time can be influenced by the operator's experience. Materials and methods: sixteen models underwent a (Cone Beam Computer Tomography) CBCT and implant positioning was digitally planned on this. The models were randomly assigned to four operators with different levels of surgical experience. One hundred and twelve implant sites were drilled using a dynamic navigation system and operating times were measured. Based on postoperative CBCTs, dental implants were virtually inserted and superimposed over the planned ones. Two-dimensional and 3D deviations between planned and virtually inserted implants were measured at the entry point and at the apical point. Angular and vertical errors were also calculated. Results: considering coronal and apical 3D deviations, no statistically significant differences were found between the four operators (p = 0.27; p = 0.06). Some vectorial components of the deviation at the apical point and the angular errors of some operators differed from each other. Conclusions: within the limitations of this study, dynamic navigation can be considered a reliable technique both for experienced and novice clinicians.

Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study / Pellegrino, Gerardo; Bellini, Pierantonio; Cavallini, Pier Francesco; Ferri, Agnese; Zacchino, Andrea; Taraschi, Valerio; Marchetti, Claudio; Consolo, Ugo. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH. - ISSN 1660-4601. - 17:6(2020), pp. 2153-2161. [10.3390/ijerph17062153]

Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study

Bellini, Pierantonio;Marchetti, Claudio;Consolo, Ugo
2020

Abstract

Aim: the aim of this in vitro study was to test whether the implant placement accuracy and the operating time can be influenced by the operator's experience. Materials and methods: sixteen models underwent a (Cone Beam Computer Tomography) CBCT and implant positioning was digitally planned on this. The models were randomly assigned to four operators with different levels of surgical experience. One hundred and twelve implant sites were drilled using a dynamic navigation system and operating times were measured. Based on postoperative CBCTs, dental implants were virtually inserted and superimposed over the planned ones. Two-dimensional and 3D deviations between planned and virtually inserted implants were measured at the entry point and at the apical point. Angular and vertical errors were also calculated. Results: considering coronal and apical 3D deviations, no statistically significant differences were found between the four operators (p = 0.27; p = 0.06). Some vectorial components of the deviation at the apical point and the angular errors of some operators differed from each other. Conclusions: within the limitations of this study, dynamic navigation can be considered a reliable technique both for experienced and novice clinicians.
2020
17
6
2153
2161
Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study / Pellegrino, Gerardo; Bellini, Pierantonio; Cavallini, Pier Francesco; Ferri, Agnese; Zacchino, Andrea; Taraschi, Valerio; Marchetti, Claudio; Consolo, Ugo. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH. - ISSN 1660-4601. - 17:6(2020), pp. 2153-2161. [10.3390/ijerph17062153]
Pellegrino, Gerardo; Bellini, Pierantonio; Cavallini, Pier Francesco; Ferri, Agnese; Zacchino, Andrea; Taraschi, Valerio; Marchetti, Claudio; Consolo, Ugo
File in questo prodotto:
File Dimensione Formato  
ijerph-17-02153-v2.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 1.73 MB
Formato Adobe PDF
1.73 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1199791
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 33
social impact