Aims Per standard of care, dual-chamber pacemakers are programmed in DDDR mode with fixed atrioventricular (AV) delay or with long AV delay to minimize ventricular pacing. We aimed to evaluate whether the PR interval may be a specific criterion of choice between standard DDDR, to preserve AV synchrony in long PR patients, and managed ventricular pacing (MVP), to avoid ventricular desynchronization imposed by right ventricle apical pacing, in short PR patients. Methods and results In the MINERVA trial, 1166 patients were randomized to Control DDDR, MVP, or atrial anti-tachycardia pacing plus MVP (DDDRP + MVP). We evaluated the interaction of PR interval with pacing mode by comparing the risk of atrial fibrillation (AF) longer than 7 consecutive days as a function of PR interval. Out of 906 patients with available data, the median PR interval was 180 ms. The PR interval was found to significantly (P = 0.012) interact with pacing mode for AF incidence: The risk of AF > 7 days was lower [hazard ratio (HR) 0.58, 95% confidence interval (95% CI) 0.34-0.99; P = 0.047] in patients with short PR (shorter than median PR) if programmed in MVP mode compared with DDDR mode and it was lower (HR 0.65, 95% CI 0.43-0.99; P = 0.049) in patients with long PR (equal to or longer than median PR) if programmed in DDDR mode compared with MVP. Conclusion Our data show that PR interval may be used as a selection criterion to identify the optimal physiological pacing mode. Persistent AF incidence was lower in short PR patients treated by right ventricular pacing minimization and in long PR patients treated by standard dual-chamber pacing.

Effect of PR interval and pacing mode on persistent atrial fibrillation incidence in dual chamber pacemaker patients: A sub-study of the international randomized MINERVA trial / Boriani, G.; Pieragnoli, P.; Botto, G. L.; Puererfellner, H.; Mont, L.; Ziacchi, M.; Manolis, A. S.; Gulizia, M.; Tukkie, R.; Landolina, M.; Ricciardi, G.; Cicconelli, M.; Grammatico, A.; Biffi, M.. - In: EUROPACE. - ISSN 1099-5129. - 21:4(2019), pp. 636-644. [10.1093/europace/euy286]

Effect of PR interval and pacing mode on persistent atrial fibrillation incidence in dual chamber pacemaker patients: A sub-study of the international randomized MINERVA trial

Boriani G.;
2019

Abstract

Aims Per standard of care, dual-chamber pacemakers are programmed in DDDR mode with fixed atrioventricular (AV) delay or with long AV delay to minimize ventricular pacing. We aimed to evaluate whether the PR interval may be a specific criterion of choice between standard DDDR, to preserve AV synchrony in long PR patients, and managed ventricular pacing (MVP), to avoid ventricular desynchronization imposed by right ventricle apical pacing, in short PR patients. Methods and results In the MINERVA trial, 1166 patients were randomized to Control DDDR, MVP, or atrial anti-tachycardia pacing plus MVP (DDDRP + MVP). We evaluated the interaction of PR interval with pacing mode by comparing the risk of atrial fibrillation (AF) longer than 7 consecutive days as a function of PR interval. Out of 906 patients with available data, the median PR interval was 180 ms. The PR interval was found to significantly (P = 0.012) interact with pacing mode for AF incidence: The risk of AF > 7 days was lower [hazard ratio (HR) 0.58, 95% confidence interval (95% CI) 0.34-0.99; P = 0.047] in patients with short PR (shorter than median PR) if programmed in MVP mode compared with DDDR mode and it was lower (HR 0.65, 95% CI 0.43-0.99; P = 0.049) in patients with long PR (equal to or longer than median PR) if programmed in DDDR mode compared with MVP. Conclusion Our data show that PR interval may be used as a selection criterion to identify the optimal physiological pacing mode. Persistent AF incidence was lower in short PR patients treated by right ventricular pacing minimization and in long PR patients treated by standard dual-chamber pacing.
2019
21
4
636
644
Effect of PR interval and pacing mode on persistent atrial fibrillation incidence in dual chamber pacemaker patients: A sub-study of the international randomized MINERVA trial / Boriani, G.; Pieragnoli, P.; Botto, G. L.; Puererfellner, H.; Mont, L.; Ziacchi, M.; Manolis, A. S.; Gulizia, M.; Tukkie, R.; Landolina, M.; Ricciardi, G.; Cicconelli, M.; Grammatico, A.; Biffi, M.. - In: EUROPACE. - ISSN 1099-5129. - 21:4(2019), pp. 636-644. [10.1093/europace/euy286]
Boriani, G.; Pieragnoli, P.; Botto, G. L.; Puererfellner, H.; Mont, L.; Ziacchi, M.; Manolis, A. S.; Gulizia, M.; Tukkie, R.; Landolina, M.; Ricciardi, G.; Cicconelli, M.; Grammatico, A.; Biffi, M.
File in questo prodotto:
File Dimensione Formato  
Effect of PR interval and pacing mode on persistent atrial fibrillation incidence.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1197907
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 17
social impact