Background: Reactive atrial-based antitachycardia pacing (rATP) aims to terminate atrial tachyarrhythmia/atrial fibrillation (AT/AF) episodes when they spontaneously organize to atrial flutter or atrial tachycardia; however, its effectiveness in the real-world has not been studied. We used a large device database (Medtronic CareLink, Medtronic, Minneapolis, MN, USA) to evaluate the effects of rATP at reducing AT/AF. Methods: Pacemaker, defibrillator, and resynchronization device transmission data were analyzed. Eligible patients had device detected AT/AF during a baseline period but were not in persistent AT/AF immediately preceding first transmission. Note that 1:1 individual matching between groups was conducted using age, sex, device type, pacing mode, AT/AF, and percent ventricular pacing at baseline. Risks of AT/AF events were compared between patients with rATP-enabled versus control patients with rATP-disabled or not available in the device. For matched patients, AT/AF event rates at 2 years were estimated by Kaplan-Meier method, and hazard ratios (HRs) were calculated by Cox proportional hazard models. Results: Of 43,440 qualifying patients, 4,203 had rATP on. Matching resulted in 4,016 pairs, totaling 8,032 patients for analysis. The rATP group experienced significantly lower risks of AT/AF events lasting ≥1 day (HR 0.81), ≥7 days (HR 0.64), and ≥30 days (HR 0.56) compared to control (P < 0.0001 for all). In subgroup analysis, rATP was associated with reduced risks of AT/AF events across age, sex, device type, baseline AT/AF, and preventive atrial pacing. Conclusions: Among real-world patients from a large device database, rATP therapy was significantly associated with a reduced risk of AT/AF. This association was independent of whether the patient had a pacemaker, defibrillator, or resynchronization device.

Reactive atrial-based antitachycardia pacing therapy reduces atrial tachyarrhythmias / Crossley, G. H.; Padeletti, L.; Zweibel, S.; Hudnall, J. H.; Zhang, Y.; Boriani, G.. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 42:7(2019), pp. 970-979. [10.1111/pace.13696]

Reactive atrial-based antitachycardia pacing therapy reduces atrial tachyarrhythmias

Boriani G.
2019

Abstract

Background: Reactive atrial-based antitachycardia pacing (rATP) aims to terminate atrial tachyarrhythmia/atrial fibrillation (AT/AF) episodes when they spontaneously organize to atrial flutter or atrial tachycardia; however, its effectiveness in the real-world has not been studied. We used a large device database (Medtronic CareLink, Medtronic, Minneapolis, MN, USA) to evaluate the effects of rATP at reducing AT/AF. Methods: Pacemaker, defibrillator, and resynchronization device transmission data were analyzed. Eligible patients had device detected AT/AF during a baseline period but were not in persistent AT/AF immediately preceding first transmission. Note that 1:1 individual matching between groups was conducted using age, sex, device type, pacing mode, AT/AF, and percent ventricular pacing at baseline. Risks of AT/AF events were compared between patients with rATP-enabled versus control patients with rATP-disabled or not available in the device. For matched patients, AT/AF event rates at 2 years were estimated by Kaplan-Meier method, and hazard ratios (HRs) were calculated by Cox proportional hazard models. Results: Of 43,440 qualifying patients, 4,203 had rATP on. Matching resulted in 4,016 pairs, totaling 8,032 patients for analysis. The rATP group experienced significantly lower risks of AT/AF events lasting ≥1 day (HR 0.81), ≥7 days (HR 0.64), and ≥30 days (HR 0.56) compared to control (P < 0.0001 for all). In subgroup analysis, rATP was associated with reduced risks of AT/AF events across age, sex, device type, baseline AT/AF, and preventive atrial pacing. Conclusions: Among real-world patients from a large device database, rATP therapy was significantly associated with a reduced risk of AT/AF. This association was independent of whether the patient had a pacemaker, defibrillator, or resynchronization device.
2019
29-apr-2019
42
7
970
979
Reactive atrial-based antitachycardia pacing therapy reduces atrial tachyarrhythmias / Crossley, G. H.; Padeletti, L.; Zweibel, S.; Hudnall, J. H.; Zhang, Y.; Boriani, G.. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 42:7(2019), pp. 970-979. [10.1111/pace.13696]
Crossley, G. H.; Padeletti, L.; Zweibel, S.; Hudnall, J. H.; Zhang, Y.; Boriani, G.
File in questo prodotto:
File Dimensione Formato  
Reactive atrial-based antitachycardia pacing therapy reduces.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 923.1 kB
Formato Adobe PDF
923.1 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1197902
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 18
social impact