In complex, large civil infrastructures where ventilation has a crucial role for the safety of users in both normal operation and hazardous scenarios, the correct prediction of flow and heat transfer parameters is of fundamental importance. While full 3D simulation is applicable only to a limited extent, and the resort to 1D modeling is a common practice in both design and evaluation phases, the limitation of such models lies in the choice of transfer parameters, such as friction loss coefficients and heat transfer coefficients. In this work, an original approach based on the Finite Volume integration of the 1D flow and energy equations is presented. Such equations are to be solved on a network of ducts, representing the ventilation system in the 11.6 km long Mont Blanc Tunnel with a spatial resolution of 10 m. A preliminary calibration of a set of friction loss coefficients against a rich experimental dataset collected throughout a dedicated set of in situ tests is of particular concern here, as it is carried out by means of genetic optimization algorithms. Predictions of the flow field are in remarkable agreement with the experimental data, with an overall RMS error of - 0.42 m/s. Further refinements and possible parameter choices are also discussed.

Development and calibration of a 1D thermo-fluid dynamic model of ventilation in tunnels / Cingi, P.; Angeli, D.; Cavazzuti, M.; Levoni, P.; Cipollone, M.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1599:1(2020), p. 012048. (Intervento presentato al convegno 37th UIT Heat Transfer Conference and Symposium Refrigerants: Heat Transfer and Applications tenutosi a University of Padova, ita nel 24-26/6/2019) [10.1088/1742-6596/1599/1/012048].

Development and calibration of a 1D thermo-fluid dynamic model of ventilation in tunnels

Cingi P.;Angeli D.;Cavazzuti M.;Levoni P.;
2020

Abstract

In complex, large civil infrastructures where ventilation has a crucial role for the safety of users in both normal operation and hazardous scenarios, the correct prediction of flow and heat transfer parameters is of fundamental importance. While full 3D simulation is applicable only to a limited extent, and the resort to 1D modeling is a common practice in both design and evaluation phases, the limitation of such models lies in the choice of transfer parameters, such as friction loss coefficients and heat transfer coefficients. In this work, an original approach based on the Finite Volume integration of the 1D flow and energy equations is presented. Such equations are to be solved on a network of ducts, representing the ventilation system in the 11.6 km long Mont Blanc Tunnel with a spatial resolution of 10 m. A preliminary calibration of a set of friction loss coefficients against a rich experimental dataset collected throughout a dedicated set of in situ tests is of particular concern here, as it is carried out by means of genetic optimization algorithms. Predictions of the flow field are in remarkable agreement with the experimental data, with an overall RMS error of - 0.42 m/s. Further refinements and possible parameter choices are also discussed.
2020
24-ago-2020
37th UIT Heat Transfer Conference and Symposium Refrigerants: Heat Transfer and Applications
University of Padova, ita
24-26/6/2019
1599
012048
Cingi, P.; Angeli, D.; Cavazzuti, M.; Levoni, P.; Cipollone, M.
Development and calibration of a 1D thermo-fluid dynamic model of ventilation in tunnels / Cingi, P.; Angeli, D.; Cavazzuti, M.; Levoni, P.; Cipollone, M.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1599:1(2020), p. 012048. (Intervento presentato al convegno 37th UIT Heat Transfer Conference and Symposium Refrigerants: Heat Transfer and Applications tenutosi a University of Padova, ita nel 24-26/6/2019) [10.1088/1742-6596/1599/1/012048].
File in questo prodotto:
File Dimensione Formato  
JOP2020.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 3.44 MB
Formato Adobe PDF
3.44 MB Adobe PDF Visualizza/Apri
2019_Cingi Angeli_XXXVII UIT.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 2.97 MB
Formato Adobe PDF
2.97 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1217824
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact