Cardiotoxicity is a well-known adverse effect of various chemotherapeutic agents that can be monitored by echocardiography. A decrease of left ventricular ejection fraction (LVEF) during the therapy might indicate dangerous effects of the drug on the myocardium and triggers consideration of therapy modification or interruption. We hypothesized myocardial deformation could identify preclinical myocardial dysfunction earlier than conventional LVEF allowing the administration of treatments to avoid cardiac side-effects. Sixty-five patients who were newly diagnosed with breast cancer, were enrolled to be evaluated by echocardiography before cancer therapy, during the therapy at 16 weeks (16w) and at follow up after 32 weeks (32w). Following the recommendation, 24 patients (36.9%) showed cardiotoxicity; 11 (16.9%) interrupted the therapy due to a severe cardiac dysfunction and at 32w only 4 patients recovered. In this group at 16w, strain analysis showed a significant reduction for all strain values that were all predictive of cardiotoxicity independently from LVEF and radial strain resulted an independent prognostic index of cardiotoxicity. The assessment of myocardial deformation indexes might provide additional echocardiographic tools to assess cardio-toxic effects beyond LVEF. © 2013 CCAL.

Early detection of cardiotoxicity in chemotherapy-treated patients from real-time 3D echocardiography / Lorenzini, Cinzia; Corsi, Cristiana; Aquilina, Michele; Casadei Gardini, Andrea; Rocca, Andrea; Frassineti, Luca; Scarpi, Emanuela; Amadori, Dino; Lamberti, Claudio. - 40:(2013), pp. 249-252. (Intervento presentato al convegno 40th Annual Meeting on Computing in Cardiology (CinC) tenutosi a Zaragoza, SPAIN nel SEP 22-25, 2013).

Early detection of cardiotoxicity in chemotherapy-treated patients from real-time 3D echocardiography

Casadei Gardini, Andrea;
2013

Abstract

Cardiotoxicity is a well-known adverse effect of various chemotherapeutic agents that can be monitored by echocardiography. A decrease of left ventricular ejection fraction (LVEF) during the therapy might indicate dangerous effects of the drug on the myocardium and triggers consideration of therapy modification or interruption. We hypothesized myocardial deformation could identify preclinical myocardial dysfunction earlier than conventional LVEF allowing the administration of treatments to avoid cardiac side-effects. Sixty-five patients who were newly diagnosed with breast cancer, were enrolled to be evaluated by echocardiography before cancer therapy, during the therapy at 16 weeks (16w) and at follow up after 32 weeks (32w). Following the recommendation, 24 patients (36.9%) showed cardiotoxicity; 11 (16.9%) interrupted the therapy due to a severe cardiac dysfunction and at 32w only 4 patients recovered. In this group at 16w, strain analysis showed a significant reduction for all strain values that were all predictive of cardiotoxicity independently from LVEF and radial strain resulted an independent prognostic index of cardiotoxicity. The assessment of myocardial deformation indexes might provide additional echocardiographic tools to assess cardio-toxic effects beyond LVEF. © 2013 CCAL.
2013
40th Annual Meeting on Computing in Cardiology (CinC)
Zaragoza, SPAIN
SEP 22-25, 2013
40
249
252
Lorenzini, Cinzia; Corsi, Cristiana; Aquilina, Michele; Casadei Gardini, Andrea; Rocca, Andrea; Frassineti, Luca; Scarpi, Emanuela; Amadori, Dino; Lamberti, Claudio
Early detection of cardiotoxicity in chemotherapy-treated patients from real-time 3D echocardiography / Lorenzini, Cinzia; Corsi, Cristiana; Aquilina, Michele; Casadei Gardini, Andrea; Rocca, Andrea; Frassineti, Luca; Scarpi, Emanuela; Amadori, Dino; Lamberti, Claudio. - 40:(2013), pp. 249-252. (Intervento presentato al convegno 40th Annual Meeting on Computing in Cardiology (CinC) tenutosi a Zaragoza, SPAIN nel SEP 22-25, 2013).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1177641
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact