Purpose: To evaluate the efficacy of biofeedback (BF) microperimetric rehabilitation in patients with Stargardt disease (STGD). Methods: Eighteen patients with STGD with unstable fixation located in the superior retina and bestcorrected visual acuity (BCVA) between 20/100 and 20/320 in the better eye were recruited. All the patients underwent Nidek MP-1 microperimetry and fixation analysis. Twelve patients underwent 8 consecutive BF training sessions of 10 minutes each, performed once a week in the better eye. Six patients did not receive any training and were used as controls. In both groups, BCVA, reading speed, contrast sensitivity, bivariate contour ellipse area (BCEA), and retinal sensitivity were evaluated in the better eye at baseline and after 10 weeks. Paired and unpaired t tests were used as appropriate. Results: In the control group, after the follow-up period, fixation pattern did not show any modification and the other parameters worsened or remained unchanged. On the contrary, the BF group showed significantly improved stabilization of fixation (mean BCEA 68.2% from 5.63°2to 1.58°2), improved mean BCVA (from 34.00 to 37.67 letters), higher mean reading speed (from 66.67 to 84.00 words/min), higher contrast sensitivity (from 16.33 to 18.75 letters), and improved retinal sensitivity (from 10.68 to 12.29 dB). The comparison of the results obtained in the 2 groups was statistically significant for all the considered parameters except for retinal sensitivity. Conclusions: Biofeedback rehabilitation with the MP-1 increases quality of vision in patients with STGD, leading to a stabilization of fixation and a consequent improvement of patients' visual function and reading abilities. © 2013 Wichtig Editore.
Biofeedback rehabilitation of eccentric fixation in patients with stargardt disease / Verdina, Tommaso; Giacomelli, Giovanni; Sodi, Andrea; Pennino, Monica; Paggini, Chiara; Murro, Vittoria; Virgili, Gianni; Menchini, Ugo. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 23:5(2013), pp. 723-731. [10.5301/ejo.5000291]
Biofeedback rehabilitation of eccentric fixation in patients with stargardt disease
Verdina, Tommaso
;Virgili, Gianni;
2013
Abstract
Purpose: To evaluate the efficacy of biofeedback (BF) microperimetric rehabilitation in patients with Stargardt disease (STGD). Methods: Eighteen patients with STGD with unstable fixation located in the superior retina and bestcorrected visual acuity (BCVA) between 20/100 and 20/320 in the better eye were recruited. All the patients underwent Nidek MP-1 microperimetry and fixation analysis. Twelve patients underwent 8 consecutive BF training sessions of 10 minutes each, performed once a week in the better eye. Six patients did not receive any training and were used as controls. In both groups, BCVA, reading speed, contrast sensitivity, bivariate contour ellipse area (BCEA), and retinal sensitivity were evaluated in the better eye at baseline and after 10 weeks. Paired and unpaired t tests were used as appropriate. Results: In the control group, after the follow-up period, fixation pattern did not show any modification and the other parameters worsened or remained unchanged. On the contrary, the BF group showed significantly improved stabilization of fixation (mean BCEA 68.2% from 5.63°2to 1.58°2), improved mean BCVA (from 34.00 to 37.67 letters), higher mean reading speed (from 66.67 to 84.00 words/min), higher contrast sensitivity (from 16.33 to 18.75 letters), and improved retinal sensitivity (from 10.68 to 12.29 dB). The comparison of the results obtained in the 2 groups was statistically significant for all the considered parameters except for retinal sensitivity. Conclusions: Biofeedback rehabilitation with the MP-1 increases quality of vision in patients with STGD, leading to a stabilization of fixation and a consequent improvement of patients' visual function and reading abilities. © 2013 Wichtig Editore.File | Dimensione | Formato | |
---|---|---|---|
ejo.5000291.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
189.02 kB
Formato
Adobe PDF
|
189.02 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris