A method to evaluate the dosimetric accuracy of volumetric modulated arc therapy (VMAT) treatment plans, generated with the MONACO (TM) (version 3.0) treatment planning system in realistic CT-data with an independent Geant4 based dose calculation algorithm is presented. Therefore a model of an Elekta Synergy linear accelerator treatment head with an MLCi2 multileaf collimator was implemented in Geant4. The time dependent linear accelerator components were modeled by importing either logfiles of an actual plan delivery or a DICOM-RT plan sequence. Absolute dose calibration, depending on a reference measurement, was applied. The MONACO as well as the Geant4 treatment head model was commissioned with lateral profiles and depth dose curves of square fields in water and with film measurements in inhomogeneous phantoms. A VMAT treatment plan for a patient with a thoracic tumor and a VMAT treatment plan of a patient, who received treatment in the thoracic spine region including metallic implants, were used for evaluation. MONACO, as well as Geant4, depth dose curves and lateral profiles of square fields had a mean local gamma (2%, 2 mm) tolerance criteria agreement of more than 95% for all fields. Film measurements in inhomogeneous phantoms with a global gamma of (3%, 3 mm) showed a pass rate above 95% in all voxels receiving more than 25% of the maximum dose. A dose-volume-histogram comparison of the VMAT patient treatment plans showed mean deviations between Geant4 and MONACO of -0.2% (first patient) and 2.0% (second patient) for the PTVs and (0.5 +/- 1.0)% and (1.4 +/- 1.1)% for the organs at risk in relation to the prescription dose. The presented method can be used to validate VMAT dose distributions generated by a large number of small segments in regions with high electron density gradients. The MONACO dose distributions showed good agreement with Geant4 and film measurements within the simulation and measurement errors.

Development of a Geant4 based Monte Carlo Algorithm to evaluate the MONACO VMAT treatment accuracy / Fleckenstein, J; Jahnke, L; Lohr, F; Wenz, F; Hesser, J. - In: ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK. - ISSN 0939-3889. - 23:1(2013), pp. 33-45. [10.1016/j.zemedi.2012.08.002]

Development of a Geant4 based Monte Carlo Algorithm to evaluate the MONACO VMAT treatment accuracy

Lohr F;
2013

Abstract

A method to evaluate the dosimetric accuracy of volumetric modulated arc therapy (VMAT) treatment plans, generated with the MONACO (TM) (version 3.0) treatment planning system in realistic CT-data with an independent Geant4 based dose calculation algorithm is presented. Therefore a model of an Elekta Synergy linear accelerator treatment head with an MLCi2 multileaf collimator was implemented in Geant4. The time dependent linear accelerator components were modeled by importing either logfiles of an actual plan delivery or a DICOM-RT plan sequence. Absolute dose calibration, depending on a reference measurement, was applied. The MONACO as well as the Geant4 treatment head model was commissioned with lateral profiles and depth dose curves of square fields in water and with film measurements in inhomogeneous phantoms. A VMAT treatment plan for a patient with a thoracic tumor and a VMAT treatment plan of a patient, who received treatment in the thoracic spine region including metallic implants, were used for evaluation. MONACO, as well as Geant4, depth dose curves and lateral profiles of square fields had a mean local gamma (2%, 2 mm) tolerance criteria agreement of more than 95% for all fields. Film measurements in inhomogeneous phantoms with a global gamma of (3%, 3 mm) showed a pass rate above 95% in all voxels receiving more than 25% of the maximum dose. A dose-volume-histogram comparison of the VMAT patient treatment plans showed mean deviations between Geant4 and MONACO of -0.2% (first patient) and 2.0% (second patient) for the PTVs and (0.5 +/- 1.0)% and (1.4 +/- 1.1)% for the organs at risk in relation to the prescription dose. The presented method can be used to validate VMAT dose distributions generated by a large number of small segments in regions with high electron density gradients. The MONACO dose distributions showed good agreement with Geant4 and film measurements within the simulation and measurement errors.
2013
23
1
33
45
Development of a Geant4 based Monte Carlo Algorithm to evaluate the MONACO VMAT treatment accuracy / Fleckenstein, J; Jahnke, L; Lohr, F; Wenz, F; Hesser, J. - In: ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK. - ISSN 0939-3889. - 23:1(2013), pp. 33-45. [10.1016/j.zemedi.2012.08.002]
Fleckenstein, J; Jahnke, L; Lohr, F; Wenz, F; Hesser, J
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0939388912001109-main.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 1.81 MB
Formato Adobe PDF
1.81 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1172482
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 21
social impact