Purpose: A susceptible-infected-susceptible (SIS) epidemic model was applied to radiation therapy (RT) treatments to predict morphological variations in head and neck (H&N) anatomy. Methods: 360 daily MVCT images of 12 H&N patients treated by tomotherapy were analyzed in this retrospective study. Deformable image registration (DIR) algorithms, mesh grids, and structure recontouring, implemented in the RayStation treatment planning system (TPS), were applied to assess the daily organ warping. The parotid's warping was evaluated using the epidemiological approach considering each vertex as a single subject and its deformed vector field (DVF) as an infection. Dedicated IronPython scripts were developed to export daily coordinates and displacements of the region of interest (ROI) from the TPS. MATLAB tools were implemented to simulate the SIS modeling. Finally, the fully trained model was applied to a new patient. Results: A QUASAR phantom was used to validate the model. The patients' validation was obtained setting 0.4 cm of vertex displacement as threshold and splitting susceptible (S) and infectious (I) cases. The correlation between the epidemiological model and the parotids' trend for further optimization of alpha and beta was carried out by Euclidean and dynamic time warping (DTW) distances. The best fit with experimental conditions across all patients (Euclidean distance of 4.09 +/- 1.12 and DTW distance of 2.39 +/- 0.66) was obtained setting the contact rate at 7.55 +/- 0.69 and the recovery rate at 2.45 +/- 0.26; birth rate was disregarded in this constant population. Conclusions: Combining an epidemiological model with adaptive RT (ART), the authors' novel approach could support image-guided radiation therapy (IGRT) to validate daily setup and to forecast anatomical variations. The SIS-ART model developed could support clinical decisions in order to optimize timing of replanning achieving personalized treatments. (C) 2016 American Association of Physicists in Medicine.

SIS epidemiological model for adaptive RT: Forecasting the parotid glands shrinkage during tomotherapy treatment / Maffei, N; Guidi, G; Vecchi, C; Ciarmatori, A; Gottardi, G; Meduri, B; D'Angelo, E; Bruni, A; Mazzeo, E; Pratissoli, S; Giacobazzi, P; Baldazzi, G; Lohr, F; Costi, T. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 43:7(2016), pp. 4294-4303. [10.1118/1.4954004]

SIS epidemiological model for adaptive RT: Forecasting the parotid glands shrinkage during tomotherapy treatment

Lohr F;
2016

Abstract

Purpose: A susceptible-infected-susceptible (SIS) epidemic model was applied to radiation therapy (RT) treatments to predict morphological variations in head and neck (H&N) anatomy. Methods: 360 daily MVCT images of 12 H&N patients treated by tomotherapy were analyzed in this retrospective study. Deformable image registration (DIR) algorithms, mesh grids, and structure recontouring, implemented in the RayStation treatment planning system (TPS), were applied to assess the daily organ warping. The parotid's warping was evaluated using the epidemiological approach considering each vertex as a single subject and its deformed vector field (DVF) as an infection. Dedicated IronPython scripts were developed to export daily coordinates and displacements of the region of interest (ROI) from the TPS. MATLAB tools were implemented to simulate the SIS modeling. Finally, the fully trained model was applied to a new patient. Results: A QUASAR phantom was used to validate the model. The patients' validation was obtained setting 0.4 cm of vertex displacement as threshold and splitting susceptible (S) and infectious (I) cases. The correlation between the epidemiological model and the parotids' trend for further optimization of alpha and beta was carried out by Euclidean and dynamic time warping (DTW) distances. The best fit with experimental conditions across all patients (Euclidean distance of 4.09 +/- 1.12 and DTW distance of 2.39 +/- 0.66) was obtained setting the contact rate at 7.55 +/- 0.69 and the recovery rate at 2.45 +/- 0.26; birth rate was disregarded in this constant population. Conclusions: Combining an epidemiological model with adaptive RT (ART), the authors' novel approach could support image-guided radiation therapy (IGRT) to validate daily setup and to forecast anatomical variations. The SIS-ART model developed could support clinical decisions in order to optimize timing of replanning achieving personalized treatments. (C) 2016 American Association of Physicists in Medicine.
2016
43
7
4294
4303
SIS epidemiological model for adaptive RT: Forecasting the parotid glands shrinkage during tomotherapy treatment / Maffei, N; Guidi, G; Vecchi, C; Ciarmatori, A; Gottardi, G; Meduri, B; D'Angelo, E; Bruni, A; Mazzeo, E; Pratissoli, S; Giacobazzi, P; Baldazzi, G; Lohr, F; Costi, T. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 43:7(2016), pp. 4294-4303. [10.1118/1.4954004]
Maffei, N; Guidi, G; Vecchi, C; Ciarmatori, A; Gottardi, G; Meduri, B; D'Angelo, E; Bruni, A; Mazzeo, E; Pratissoli, S; Giacobazzi, P; Baldazzi, G; Lo...espandi
File in questo prodotto:
File Dimensione Formato  
1.4954004.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 5.24 MB
Formato Adobe PDF
5.24 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1172438
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact