Background and purpose: Reported plan quality improvements with autoplanning of radiotherapy of the prostate and seminal vesicles are poor. A system for automated multi-criterial planning has been validated for this treatment in a large international multi-center study. The system is configured with training plans using a mechanism that strives for quality improvements relative to those plans. Material and methods: Each of the four participating centers included thirty manually generated clinical Volumetric Modulated Arc Therapy prostate plans (manVMAT). Ten plans were used for autoplanning training. The other twenty were compared with an automatically generated plan (autoVMAT). Plan evaluations considered dosimetric plan parameters and blinded side-by-side plan comparisons by clinicians. Results: With equivalent Planning Target Volume (PTV) V95%, D2%, D98%, and dose homogeneity autoVMAT was overall superior for rectum with median differences of 3.4 Gy (p < 0.001) in Dmean, 4.0% (p < 0.001) in V60Gy, and 1.5% (p = 0.001) in V75Gy, and for bladder Dmean (0.9 Gy, p < 0.001). Also the clinicians’ plan comparisons pointed at an overall preference for autoVMAT. Advantages of autoVMAT were highly treatment center- and patient-specific with overall ranges for differences in rectum Dmean and V60Gy of [−4,12] Gy and [−2,15]%, respectively. Conclusion: Observed advantages of autoplanning were clinically relevant and larger than reported in the literature. The latter is likely related to the multi-criterial nature of the applied autoplanning algorithm, with for each center a dedicated configuration that aims at plan improvements relative to its (clinical) training plans. Large variations among patients in differences between manVMAT and autoVMAT point at inconsistencies in manual planning.

Fully automated, multi-criterial planning for Volumetric Modulated Arc Therapy – An international multi-center validation for prostate cancer / Heijmen, Ben; Voet, Peter; Fransen, Dennie; Penninkhof, Joan; Milder, Maaike; Akhiat, Hafid; Bonomo, Pierluigi; Casati, Marta; Georg, Dietmar; Goldner, Gregor; Henry, Ann; Lilley, John; Lohr, Frank; Marrazzo, Livia; Pallotta, Stefania; Pellegrini, Roberto; Seppenwoolde, Yvette; Simontacchi, Gabriele; Steil, Volker; Stieler, Florian; Wilson, Stuart; Breedveld, Sebastiaan. - In: RADIOTHERAPY AND ONCOLOGY. - ISSN 0167-8140. - 128:2(2018), pp. 343-348. [10.1016/j.radonc.2018.06.023]

Fully automated, multi-criterial planning for Volumetric Modulated Arc Therapy – An international multi-center validation for prostate cancer

Lohr, Frank;
2018

Abstract

Background and purpose: Reported plan quality improvements with autoplanning of radiotherapy of the prostate and seminal vesicles are poor. A system for automated multi-criterial planning has been validated for this treatment in a large international multi-center study. The system is configured with training plans using a mechanism that strives for quality improvements relative to those plans. Material and methods: Each of the four participating centers included thirty manually generated clinical Volumetric Modulated Arc Therapy prostate plans (manVMAT). Ten plans were used for autoplanning training. The other twenty were compared with an automatically generated plan (autoVMAT). Plan evaluations considered dosimetric plan parameters and blinded side-by-side plan comparisons by clinicians. Results: With equivalent Planning Target Volume (PTV) V95%, D2%, D98%, and dose homogeneity autoVMAT was overall superior for rectum with median differences of 3.4 Gy (p < 0.001) in Dmean, 4.0% (p < 0.001) in V60Gy, and 1.5% (p = 0.001) in V75Gy, and for bladder Dmean (0.9 Gy, p < 0.001). Also the clinicians’ plan comparisons pointed at an overall preference for autoVMAT. Advantages of autoVMAT were highly treatment center- and patient-specific with overall ranges for differences in rectum Dmean and V60Gy of [−4,12] Gy and [−2,15]%, respectively. Conclusion: Observed advantages of autoplanning were clinically relevant and larger than reported in the literature. The latter is likely related to the multi-criterial nature of the applied autoplanning algorithm, with for each center a dedicated configuration that aims at plan improvements relative to its (clinical) training plans. Large variations among patients in differences between manVMAT and autoVMAT point at inconsistencies in manual planning.
2018
30-giu-2018
128
2
343
348
Fully automated, multi-criterial planning for Volumetric Modulated Arc Therapy – An international multi-center validation for prostate cancer / Heijmen, Ben; Voet, Peter; Fransen, Dennie; Penninkhof, Joan; Milder, Maaike; Akhiat, Hafid; Bonomo, Pierluigi; Casati, Marta; Georg, Dietmar; Goldner, Gregor; Henry, Ann; Lilley, John; Lohr, Frank; Marrazzo, Livia; Pallotta, Stefania; Pellegrini, Roberto; Seppenwoolde, Yvette; Simontacchi, Gabriele; Steil, Volker; Stieler, Florian; Wilson, Stuart; Breedveld, Sebastiaan. - In: RADIOTHERAPY AND ONCOLOGY. - ISSN 0167-8140. - 128:2(2018), pp. 343-348. [10.1016/j.radonc.2018.06.023]
Heijmen, Ben; Voet, Peter; Fransen, Dennie; Penninkhof, Joan; Milder, Maaike; Akhiat, Hafid; Bonomo, Pierluigi; Casati, Marta; Georg, Dietmar; Goldner, Gregor; Henry, Ann; Lilley, John; Lohr, Frank; Marrazzo, Livia; Pallotta, Stefania; Pellegrini, Roberto; Seppenwoolde, Yvette; Simontacchi, Gabriele; Steil, Volker; Stieler, Florian; Wilson, Stuart; Breedveld, Sebastiaan
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0167814018333383-main (1).pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 684.87 kB
Formato Adobe PDF
684.87 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1172308
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 60
social impact