Background: Postoperative/adjuvant radiotherapy of advanced gastric cancer involves a large planning target volume (PTV) with multi-concave shapes which presents a challenge for volumetric modulated arc therapy (VMAT) planning. This study investigates the advantages of automated VMAT planning for this site compared to manual VMAT planning by expert planners. Methods: For 20 gastric cancer patients in the postoperative/adjuvant setting, dual-arc VMAT plans were generated using fully automated multi-criterial treatment planning (autoVMAT), and compared to manually generated VMAT plans (manVMAT). Both automated and manual plans were created to deliver a median dose of 45 Gy to the PTV using identical planning and segmentation parameters. Plans were evaluated by two expert radiation oncologists for clinical acceptability. AutoVMAT and manVMAT plans were also compared based on dose-volume histogram (DVH) and predicted normal tissue complication probability (NTCP) analysis. Results: Both manVMAT and autoVMAT plans were considered clinically acceptable. Target coverage was similar (manVMAT: 96.6±1.6%, autoVMAT: 97.4±1.0%, p=0.085). With autoVMAT, median kidney dose was reduced on average by >25%; (for left kidney from 11.3±2.1 Gy to 8.9±3.5 Gy (p=0.002); for right kidney from 9.2±2.2 Gy to 6.1±1.3 Gy (p< 0.001)). Median dose to the liver was lower as well (18.8±2.3 Gy vs. 17.1±3.6 Gy, p=0.048). In addition, Dmax of the spinal cord was significantly reduced (38.3±3.7 Gy vs. 31.6±2.6 Gy, p< 0.001). Substantial improvements in dose conformity and integral dose were achieved with autoVMAT plans (4.2% and 9.1%, respectively; p< 0.001). Due to the better OAR sparing in the autoVMAT plans compared to manVMAT plans, the predicted NTCPs for the left and right kidney and the liver-PTV were significantly reduced by 11.3%, 12.8%, 7%, respectively (p≤0.001). Delivery time and total number of monitor units were increased in autoVMAT plans (from 168±19 s to 207±26 s, p=0.006) and (from 781±168 MU to 1001±134 MU, p=0.003), respectively. Conclusions: For postoperative/adjuvant radiotherapy of advanced gastric cancer, involving a complex target shape, automated VMAT planning is feasible and can substantially reduce the dose to the kidneys and the liver, without compromising the target dose delivery.

Automated VMAT planning for postoperative adjuvant treatment of advanced gastric cancer / Sharfo, Abdul Wahab M.; Stieler, Florian; Kupfer, Oskar; Heijmen, Ben J. M.; Dirkx, Maarten L. P.; Breedveld, Sebastiaan; Wenz, Frederik; Lohr, Frank; Boda-Heggemann, Judit; Buergy, Daniel. - In: RADIATION ONCOLOGY. - ISSN 1748-717X. - 13:1(2018), pp. 1-8. [10.1186/s13014-018-1032-z]

Automated VMAT planning for postoperative adjuvant treatment of advanced gastric cancer

Lohr, Frank;
2018

Abstract

Background: Postoperative/adjuvant radiotherapy of advanced gastric cancer involves a large planning target volume (PTV) with multi-concave shapes which presents a challenge for volumetric modulated arc therapy (VMAT) planning. This study investigates the advantages of automated VMAT planning for this site compared to manual VMAT planning by expert planners. Methods: For 20 gastric cancer patients in the postoperative/adjuvant setting, dual-arc VMAT plans were generated using fully automated multi-criterial treatment planning (autoVMAT), and compared to manually generated VMAT plans (manVMAT). Both automated and manual plans were created to deliver a median dose of 45 Gy to the PTV using identical planning and segmentation parameters. Plans were evaluated by two expert radiation oncologists for clinical acceptability. AutoVMAT and manVMAT plans were also compared based on dose-volume histogram (DVH) and predicted normal tissue complication probability (NTCP) analysis. Results: Both manVMAT and autoVMAT plans were considered clinically acceptable. Target coverage was similar (manVMAT: 96.6±1.6%, autoVMAT: 97.4±1.0%, p=0.085). With autoVMAT, median kidney dose was reduced on average by >25%; (for left kidney from 11.3±2.1 Gy to 8.9±3.5 Gy (p=0.002); for right kidney from 9.2±2.2 Gy to 6.1±1.3 Gy (p< 0.001)). Median dose to the liver was lower as well (18.8±2.3 Gy vs. 17.1±3.6 Gy, p=0.048). In addition, Dmax of the spinal cord was significantly reduced (38.3±3.7 Gy vs. 31.6±2.6 Gy, p< 0.001). Substantial improvements in dose conformity and integral dose were achieved with autoVMAT plans (4.2% and 9.1%, respectively; p< 0.001). Due to the better OAR sparing in the autoVMAT plans compared to manVMAT plans, the predicted NTCPs for the left and right kidney and the liver-PTV were significantly reduced by 11.3%, 12.8%, 7%, respectively (p≤0.001). Delivery time and total number of monitor units were increased in autoVMAT plans (from 168±19 s to 207±26 s, p=0.006) and (from 781±168 MU to 1001±134 MU, p=0.003), respectively. Conclusions: For postoperative/adjuvant radiotherapy of advanced gastric cancer, involving a complex target shape, automated VMAT planning is feasible and can substantially reduce the dose to the kidneys and the liver, without compromising the target dose delivery.
2018
13
1
1
8
Automated VMAT planning for postoperative adjuvant treatment of advanced gastric cancer / Sharfo, Abdul Wahab M.; Stieler, Florian; Kupfer, Oskar; Heijmen, Ben J. M.; Dirkx, Maarten L. P.; Breedveld, Sebastiaan; Wenz, Frederik; Lohr, Frank; Boda-Heggemann, Judit; Buergy, Daniel. - In: RADIATION ONCOLOGY. - ISSN 1748-717X. - 13:1(2018), pp. 1-8. [10.1186/s13014-018-1032-z]
Sharfo, Abdul Wahab M.; Stieler, Florian; Kupfer, Oskar; Heijmen, Ben J. M.; Dirkx, Maarten L. P.; Breedveld, Sebastiaan; Wenz, Frederik; Lohr, Frank; Boda-Heggemann, Judit; Buergy, Daniel
File in questo prodotto:
File Dimensione Formato  
s13014-018-1032-z.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 1.89 MB
Formato Adobe PDF
1.89 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1172306
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 17
social impact