Objectives: Plaque accumulation and mechanical wear are two main risk factors of implant-prosthetic failure. To reduce the occurrence of these complications, prototypical abutments ("Star Abutment”, PhD Course in Industrial and Environmental Engineering, Modena, Italy) were realised and the literature reviewed to identify eligible coatings for enhancing mechanical and chemical surface properties. Zirconium Nitride (ZrN), Diamond-Like Carbon (DLC), and Superlattice CrN/NbN (CrN/NbN) coated some abutments, and then Neutral Red Uptake Cytotoxicity Direct Contact Test was performed to primarily evaluate the biocompatibility of these surfaces. Methods: Four specimens for each test group were sterilized, then each group placed in a plate directly contacting with Dulbecco’s modified Eagle's medium (DMEM) (Invitrogen, Karlshue, Germany) containing BALB/3T3 murine fibroblasts (Istituto Zooprofilattico, Brescia, Italy) at standard temperature (37°C±1°C), humidity (90%± 5%) and CO2 concentration (5%±1%). Two additional plates were used as positive (DMEM with 0.45% phenol solution) and negative (DMEM) control groups. Samples were analyzed at 24, 48 and 72 hours with optical microscope (Nikon, Japan) for cytomorphological evaluation and, after treatment with 0.2% Neutral Red, spectrophotometry analysis (HP 8452A Diode-Array, Hewlett-Packard, USA) was performed with λ set at 540nm to obtain fibroblasts survival rates for each test and control group: non-coated (NC), ZrN-coated, DLC-coated, CrN/NbN-coated, negative control (CTRL-) and positive control (CTRL+). Results: Optical analysis showed no inhibition halo for each test specimens at 24, 48 and 72 hours. Spectrophotometry analysis showed no cytotoxicity for each test specimens at 24, 48 and 72 hours. Detailed results are reported in the attached graphics. Conclusions: ZrN, DLC, and CrN/NbN coatings showed no cytotoxicity with BALB/3T3 murine fibroblasts after 24, 48 and 72 hours. These results encourage the research on Star Abutments. Up to January 2018, this seems to be the first application of a Superlattice CrN/NbN coating in dentistry.

In-Vitro Cytotoxicity Evaluation of Three Low-Friction Abutment Coatings / Giavatto, M. A.; Consolo, U.; Bortolini, S.; Bianchi, A.; Natali, A; Giannatiempo, J; Cucchi, A; Bellucci, D; Salvatori, R; Cannillo, V.. - In: JOURNAL OF DENTAL RESEARCH. - ISSN 1544-0591. - IADR 2018(2018). (Intervento presentato al convegno International Association for Dental Research (IADR) tenutosi a London, England nel 25-28/07/2018).

In-Vitro Cytotoxicity Evaluation of Three Low-Friction Abutment Coatings

Consolo U.;Bortolini S.;Bianchi A.;Natali A;Bellucci D;Salvatori R
Membro del Collaboration Group
;
Cannillo V.
2018

Abstract

Objectives: Plaque accumulation and mechanical wear are two main risk factors of implant-prosthetic failure. To reduce the occurrence of these complications, prototypical abutments ("Star Abutment”, PhD Course in Industrial and Environmental Engineering, Modena, Italy) were realised and the literature reviewed to identify eligible coatings for enhancing mechanical and chemical surface properties. Zirconium Nitride (ZrN), Diamond-Like Carbon (DLC), and Superlattice CrN/NbN (CrN/NbN) coated some abutments, and then Neutral Red Uptake Cytotoxicity Direct Contact Test was performed to primarily evaluate the biocompatibility of these surfaces. Methods: Four specimens for each test group were sterilized, then each group placed in a plate directly contacting with Dulbecco’s modified Eagle's medium (DMEM) (Invitrogen, Karlshue, Germany) containing BALB/3T3 murine fibroblasts (Istituto Zooprofilattico, Brescia, Italy) at standard temperature (37°C±1°C), humidity (90%± 5%) and CO2 concentration (5%±1%). Two additional plates were used as positive (DMEM with 0.45% phenol solution) and negative (DMEM) control groups. Samples were analyzed at 24, 48 and 72 hours with optical microscope (Nikon, Japan) for cytomorphological evaluation and, after treatment with 0.2% Neutral Red, spectrophotometry analysis (HP 8452A Diode-Array, Hewlett-Packard, USA) was performed with λ set at 540nm to obtain fibroblasts survival rates for each test and control group: non-coated (NC), ZrN-coated, DLC-coated, CrN/NbN-coated, negative control (CTRL-) and positive control (CTRL+). Results: Optical analysis showed no inhibition halo for each test specimens at 24, 48 and 72 hours. Spectrophotometry analysis showed no cytotoxicity for each test specimens at 24, 48 and 72 hours. Detailed results are reported in the attached graphics. Conclusions: ZrN, DLC, and CrN/NbN coatings showed no cytotoxicity with BALB/3T3 murine fibroblasts after 24, 48 and 72 hours. These results encourage the research on Star Abutments. Up to January 2018, this seems to be the first application of a Superlattice CrN/NbN coating in dentistry.
2018
Giavatto, M. A.; Consolo, U.; Bortolini, S.; Bianchi, A.; Natali, A; Giannatiempo, J; Cucchi, A; Bellucci, D; Salvatori, R; Cannillo, V.
In-Vitro Cytotoxicity Evaluation of Three Low-Friction Abutment Coatings / Giavatto, M. A.; Consolo, U.; Bortolini, S.; Bianchi, A.; Natali, A; Giannatiempo, J; Cucchi, A; Bellucci, D; Salvatori, R; Cannillo, V.. - In: JOURNAL OF DENTAL RESEARCH. - ISSN 1544-0591. - IADR 2018(2018). (Intervento presentato al convegno International Association for Dental Research (IADR) tenutosi a London, England nel 25-28/07/2018).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1171641
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact