Early detection of incipient faults in AC drives is one of the most difficult challenges for condition monitoring, especially for faults related to insulation degradation of the windings. In low power motors, the insulation degradations are principally due to the steep voltage variations caused by the voltage source converters (VSCs) that drive the machines. In the last years, the possibility to employ coaxial cables in the stator windings has been explored in order to enhance the capacity of the motors to withstand the great values of dv/dt that are achieved by the no-Si based power devices. In this paper a new method to detect the presence of incipient faults in PMSM with coaxial insulated winding is presented and compared with a previous solution. The different methods were extensively evaluated, by means simulations and experimental results, to determine their feasibility to be employed as on-line condition monitoring systems.

Comparison of different methods for incipient fault diagnosis in PMSMs with coaxial insulated windings / Barater, Davide; Arellano-Padilla, Jesus; Gerada, Chris. - (2014), pp. 1737-1744. (Intervento presentato al convegno IEEE Energy Conversion Congress and Exposition (ECCE) tenutosi a Pittsburgh, PA, USA nel SEP 14-18, 2014) [10.1109/ECCE.2014.6953628].

Comparison of different methods for incipient fault diagnosis in PMSMs with coaxial insulated windings

Barater, Davide;
2014

Abstract

Early detection of incipient faults in AC drives is one of the most difficult challenges for condition monitoring, especially for faults related to insulation degradation of the windings. In low power motors, the insulation degradations are principally due to the steep voltage variations caused by the voltage source converters (VSCs) that drive the machines. In the last years, the possibility to employ coaxial cables in the stator windings has been explored in order to enhance the capacity of the motors to withstand the great values of dv/dt that are achieved by the no-Si based power devices. In this paper a new method to detect the presence of incipient faults in PMSM with coaxial insulated winding is presented and compared with a previous solution. The different methods were extensively evaluated, by means simulations and experimental results, to determine their feasibility to be employed as on-line condition monitoring systems.
2014
IEEE Energy Conversion Congress and Exposition (ECCE)
Pittsburgh, PA, USA
SEP 14-18, 2014
1737
1744
Barater, Davide; Arellano-Padilla, Jesus; Gerada, Chris
Comparison of different methods for incipient fault diagnosis in PMSMs with coaxial insulated windings / Barater, Davide; Arellano-Padilla, Jesus; Gerada, Chris. - (2014), pp. 1737-1744. (Intervento presentato al convegno IEEE Energy Conversion Congress and Exposition (ECCE) tenutosi a Pittsburgh, PA, USA nel SEP 14-18, 2014) [10.1109/ECCE.2014.6953628].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1170942
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact