A new ultralow-temperature setup dedicated to soft X-ray absorption spectroscopy and X-ray magnetic circular dichroism (XMCD) experiments is described. Two experiments, performed on the DEIMOS beamline (SOLEIL synchrotron), demonstrate the outstanding performance of this new platform in terms of the lowest achievable temperature under X-ray irradiation (T = 220 mK), the precision in controlling the temperature during measurements as well as the speed of the cooling-down and warming-up procedures. Moreover, owing to the new design of the setup, the eddy-current power is strongly reduced, allowing fast scanning of the magnetic field in XMCD experiments; these performances lead to a powerful device for X-ray spectroscopies on synchrotron-radiation beamlines facilities.

Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments / Kappler, J. -P.; Otero, E.; Li, Weicheng; Joly, L.; Schmerber, G.; Muller, B.; Scheurer, F.; Leduc, F.; Gobaut, B.; Poggini, L.; Serrano, G.; Choueikani, F.; Lhotel, E.; Cornia, A.; Sessoli, R.; Mannini, M.; Arrio, M. -A.; Sainctavit, Ph.; Ohresser, P.. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 0909-0495. - 25:6(2018), pp. 1727-1735. [10.1107/S1600577518012717]

Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments

LI, WEICHENG;Cornia, A.;
2018

Abstract

A new ultralow-temperature setup dedicated to soft X-ray absorption spectroscopy and X-ray magnetic circular dichroism (XMCD) experiments is described. Two experiments, performed on the DEIMOS beamline (SOLEIL synchrotron), demonstrate the outstanding performance of this new platform in terms of the lowest achievable temperature under X-ray irradiation (T = 220 mK), the precision in controlling the temperature during measurements as well as the speed of the cooling-down and warming-up procedures. Moreover, owing to the new design of the setup, the eddy-current power is strongly reduced, allowing fast scanning of the magnetic field in XMCD experiments; these performances lead to a powerful device for X-ray spectroscopies on synchrotron-radiation beamlines facilities.
2018
19-ott-2018
25
6
1727
1735
Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments / Kappler, J. -P.; Otero, E.; Li, Weicheng; Joly, L.; Schmerber, G.; Muller, B.; Scheurer, F.; Leduc, F.; Gobaut, B.; Poggini, L.; Serrano, G.; Choueikani, F.; Lhotel, E.; Cornia, A.; Sessoli, R.; Mannini, M.; Arrio, M. -A.; Sainctavit, Ph.; Ohresser, P.. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 0909-0495. - 25:6(2018), pp. 1727-1735. [10.1107/S1600577518012717]
Kappler, J. -P.; Otero, E.; Li, Weicheng; Joly, L.; Schmerber, G.; Muller, B.; Scheurer, F.; Leduc, F.; Gobaut, B.; Poggini, L.; Serrano, G.; Choueikani, F.; Lhotel, E.; Cornia, A.; Sessoli, R.; Mannini, M.; Arrio, M. -A.; Sainctavit, Ph.; Ohresser, P.
File in questo prodotto:
File Dimensione Formato  
il5017.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 1.27 MB
Formato Adobe PDF
1.27 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1169920
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 16
social impact