Background: In patients with cardiac implanted electronic devices, detection of new atrial fibrillation (AF) is associated with an increased risk of stroke. Objective: To characterize daily AF burden at first detection and the rate of temporal transition to higher device-detected AF burden. Methods: A pooled analysis of data from 3 prospective projects was analyzed, and 6580 patients (mean age 68 ± 12 years, 72% male) with no history of AF and no use of anticoagulants at baseline were identified. Various thresholds of daily AF burden (5 minutes and 1, 6, 12, and 23 hours) were analyzed. Results: Among the study population of 6580 patients, a new AF, with an AF burden of ≥5 minutes, was detected in 2244 patients (34%) during a follow-up period of 2.4 ± 1.7 years. Among these patients, 1091 (49.8%) transitioned to a higher AF-burden threshold during follow-up. A higher duration of daily AF burden manifest at first detection and CHADS2 score ≥2 were associated with faster transition to a subsequent higher burden. Approximately 24% of patients transitioned from a lower threshold to a daily AF burden of ≥23 hours during follow-up. Conclusion: More than one-third of patients with no history of AF developed device-detected AF, with attainment of different thresholds of daily AF burden over time. Continuous long-term monitoring, especially when the initial detection corresponds to a higher daily AF burden and the CHADS2 score is ≥2, could support timely clinical decisions on anticoagulation by capturing transitions to higher AF-burden thresholds.
Detection of new atrial fibrillation in patients with cardiac implanted electronic devices and factors associated with transition to higher device-detected atrial fibrillation burden / Boriani, Giuseppe; Glotzer, Taya V.; Ziegler, Paul D.; De Melis, Mirko; Mangoni di S. Stefano, Lorenza; Sepsi, Milan; Landolina, Maurizio; Lunati, Maurizio; Lewalter, Thorsten; Camm, A. John. - In: HEART RHYTHM. - ISSN 1547-5271. - 15:3(2018), pp. 376-383. [10.1016/j.hrthm.2017.11.007]
Detection of new atrial fibrillation in patients with cardiac implanted electronic devices and factors associated with transition to higher device-detected atrial fibrillation burden
Boriani, Giuseppe;
2018
Abstract
Background: In patients with cardiac implanted electronic devices, detection of new atrial fibrillation (AF) is associated with an increased risk of stroke. Objective: To characterize daily AF burden at first detection and the rate of temporal transition to higher device-detected AF burden. Methods: A pooled analysis of data from 3 prospective projects was analyzed, and 6580 patients (mean age 68 ± 12 years, 72% male) with no history of AF and no use of anticoagulants at baseline were identified. Various thresholds of daily AF burden (5 minutes and 1, 6, 12, and 23 hours) were analyzed. Results: Among the study population of 6580 patients, a new AF, with an AF burden of ≥5 minutes, was detected in 2244 patients (34%) during a follow-up period of 2.4 ± 1.7 years. Among these patients, 1091 (49.8%) transitioned to a higher AF-burden threshold during follow-up. A higher duration of daily AF burden manifest at first detection and CHADS2 score ≥2 were associated with faster transition to a subsequent higher burden. Approximately 24% of patients transitioned from a lower threshold to a daily AF burden of ≥23 hours during follow-up. Conclusion: More than one-third of patients with no history of AF developed device-detected AF, with attainment of different thresholds of daily AF burden over time. Continuous long-term monitoring, especially when the initial detection corresponds to a higher daily AF burden and the CHADS2 score is ≥2, could support timely clinical decisions on anticoagulation by capturing transitions to higher AF-burden thresholds.File | Dimensione | Formato | |
---|---|---|---|
boriani2017.pdf
Open access
Tipologia:
Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione
877.25 kB
Formato
Adobe PDF
|
877.25 kB | Adobe PDF | Visualizza/Apri |
VOR_Detection of new atrial fibrillation in patients with cardiac.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
3.73 MB
Formato
Adobe PDF
|
3.73 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris