The management of patients with a cardiac implanted electronic device (CIED) receiving radiotherapy (RT) is challenging and requires a structured multidisciplinary approach. A consensus document is presented as a result of a multidisciplinary working group involving cardiac electrophysiologists, radiation oncologists and physicists in order to stratify the risk of patients with CIED requiring RT and approaching RT sessions appropriately. When high radiation doses and beam energy higher than 6 MV are used, CIED malfunctions can occur during treatment. In our document, we reviewed the different types of RT and CIED behavior in the presence of ionizing radiations and electromagnetic interferences, from the cardiologist's, radiation oncologist's and medical physicist's point of view. We also reviewed in vitro and in vivo literature data and other national published guidelines on this issue so far. On the basis of literature data and consensus of experts, a detailed approach based on risk stratification and appropriate management of RT patients with CIEDs is suggested, with important implications for clinical practice.

Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: A consensus document from Associazione Italiana Aritmologia e Cardiostimolazione (AIAC), Associazione Italiana Radioterapia Oncologica (AIRO), Associazione Italiana Fisica Medica (AIFM) / Zecchin, Massimo; Severgnini, Mara; Fiorentino, Alba; Malavasi, Vincenzo Livio; Menegotti, Loris; Alongi, Filippo; Catanzariti, Domenico; Jereczek-Fossa, Barbara Alicja; Stasi, Michele; Russi, Elvio; Boriani, Giuseppe. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 255:(2018), pp. 175-183. [10.1016/j.ijcard.2017.12.061]

Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: A consensus document from Associazione Italiana Aritmologia e Cardiostimolazione (AIAC), Associazione Italiana Radioterapia Oncologica (AIRO), Associazione Italiana Fisica Medica (AIFM)

Boriani, Giuseppe
2018

Abstract

The management of patients with a cardiac implanted electronic device (CIED) receiving radiotherapy (RT) is challenging and requires a structured multidisciplinary approach. A consensus document is presented as a result of a multidisciplinary working group involving cardiac electrophysiologists, radiation oncologists and physicists in order to stratify the risk of patients with CIED requiring RT and approaching RT sessions appropriately. When high radiation doses and beam energy higher than 6 MV are used, CIED malfunctions can occur during treatment. In our document, we reviewed the different types of RT and CIED behavior in the presence of ionizing radiations and electromagnetic interferences, from the cardiologist's, radiation oncologist's and medical physicist's point of view. We also reviewed in vitro and in vivo literature data and other national published guidelines on this issue so far. On the basis of literature data and consensus of experts, a detailed approach based on risk stratification and appropriate management of RT patients with CIEDs is suggested, with important implications for clinical practice.
2018
24-dic-2017
255
175
183
Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: A consensus document from Associazione Italiana Aritmologia e Cardiostimolazione (AIAC), Associazione Italiana Radioterapia Oncologica (AIRO), Associazione Italiana Fisica Medica (AIFM) / Zecchin, Massimo; Severgnini, Mara; Fiorentino, Alba; Malavasi, Vincenzo Livio; Menegotti, Loris; Alongi, Filippo; Catanzariti, Domenico; Jereczek-Fossa, Barbara Alicja; Stasi, Michele; Russi, Elvio; Boriani, Giuseppe. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 255:(2018), pp. 175-183. [10.1016/j.ijcard.2017.12.061]
Zecchin, Massimo; Severgnini, Mara; Fiorentino, Alba; Malavasi, Vincenzo Livio; Menegotti, Loris; Alongi, Filippo; Catanzariti, Domenico; Jereczek-Fos...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0167527317352877-main.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 1.4 MB
Formato Adobe PDF
1.4 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1168109
Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 63
social impact