Cardiac resynchronization therapy (CRT) is an established treatment in patients with symptomatic drug-refractory heart failure and broad QRS complex on the surface ECG. Despite the presence of either mechanical dyssynchrony or viable myocardium at the site where delivering left ventricular pacing being necessary conditions for a successfulCRT, their direct assessment by techniques of cardiovascular imaging, though feasible, is not recommended in clinical practice by the current guidelines. Indeed, even though there is growing body of data providing evidence of the additional value of an image-based approach as compared with routine approach in improving response to CRT, these results should be confirmed in prospective and large multicentre trials before their impact on CRT guidelines is considered.
Role of cardiovascular imaging in cardiac resynchronization therapy: A literature review / Sassone, Biagio; Nucifora, Gaetano; Mele, Donato; Valzania, Cinzia; Bisignani, Giovanni; Boriani, Giuseppe. - In: JOURNAL OF CARDIOVASCULAR MEDICINE. - ISSN 1558-2027. - 19:5(2018), pp. 211-222. [10.2459/JCM.0000000000000635]
Role of cardiovascular imaging in cardiac resynchronization therapy: A literature review
Boriani, Giuseppe
2018
Abstract
Cardiac resynchronization therapy (CRT) is an established treatment in patients with symptomatic drug-refractory heart failure and broad QRS complex on the surface ECG. Despite the presence of either mechanical dyssynchrony or viable myocardium at the site where delivering left ventricular pacing being necessary conditions for a successfulCRT, their direct assessment by techniques of cardiovascular imaging, though feasible, is not recommended in clinical practice by the current guidelines. Indeed, even though there is growing body of data providing evidence of the additional value of an image-based approach as compared with routine approach in improving response to CRT, these results should be confirmed in prospective and large multicentre trials before their impact on CRT guidelines is considered.File | Dimensione | Formato | |
---|---|---|---|
sassone2018.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
891.02 kB
Formato
Adobe PDF
|
891.02 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris