Motion analysis is based on measuring trajectories, rotations of joints, torque values, temporal events, and muscle activities. Force plates embedded in the floors of motion analysis laboratories measure force transfer between foot and ground during gait. Kinematics, kinetics, and surface electromyography (sEMG) are used to identify the causes of motion impairment and the resulting compensatory movements, thus enhancing clinical assessment and supporting decisions such as choice of surgery, orthoses, and rehabilitation protocols. Surface EMG can provide information on the origin of motion produced by muscle activation. EMG during task execution enables muscle activities to be assessed rather than inferred from a combination of observation of movements and clinical evaluation performed under static conditions. To ensure data reliability in applications of motion analysis, raw sEMG data on a fixed y-axis scale must be checked before five criteria: filtering, envelope computation, data normalization, clinical report creation, and statistical analysis for research purposes.

Applications in movement and gait analysis / Merlo, A.; Campanini, I.. - (2016), pp. 440-459. [10.1002/9781119082934.ch16]

Applications in movement and gait analysis

Merlo, A.;Campanini, I.
2016

Abstract

Motion analysis is based on measuring trajectories, rotations of joints, torque values, temporal events, and muscle activities. Force plates embedded in the floors of motion analysis laboratories measure force transfer between foot and ground during gait. Kinematics, kinetics, and surface electromyography (sEMG) are used to identify the causes of motion impairment and the resulting compensatory movements, thus enhancing clinical assessment and supporting decisions such as choice of surgery, orthoses, and rehabilitation protocols. Surface EMG can provide information on the origin of motion produced by muscle activation. EMG during task execution enables muscle activities to be assessed rather than inferred from a combination of observation of movements and clinical evaluation performed under static conditions. To ensure data reliability in applications of motion analysis, raw sEMG data on a fixed y-axis scale must be checked before five criteria: filtering, envelope computation, data normalization, clinical report creation, and statistical analysis for research purposes.
2016
22-apr-2016
Surface Electromyography: Physiology, Engineering and Applications
9781119082934
wiley
Applications in movement and gait analysis / Merlo, A.; Campanini, I.. - (2016), pp. 440-459. [10.1002/9781119082934.ch16]
Merlo, A.; Campanini, I.
File in questo prodotto:
File Dimensione Formato  
C16_amended.pdf

Accesso riservato

Tipologia: Versione originale dell'autore proposta per la pubblicazione
Dimensione 1.52 MB
Formato Adobe PDF
1.52 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1164320
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? ND
social impact