Purpose: The aim of this study was to assess the effectiveness of reverse total shoulder arthroplasty (RTSA) with an all-polyethylene glenosphere in patients with failed hemiarthroplasty (HH) or the sequelae of proximal humeral fractures. Methods: Thirty-six patients were assessed at a mean follow-up of 36 months using clinical scores and recording shoulder range of movement (ROM). Results: Active anterior elevation (p < 0.001), lateral elevation (p < 0.001) and internal rotation (p < 0.0001) improved significantly, whereas improvement in external rotation was not significant. The mean Constant score rose significantly from 8.5 ± 7.6 to 40.7 ± 15.7 (p < 0.001) and the Simple Shoulder Test score from 0.42 ± 0.85 to 5.5 ± 2.6 (p < 0.001). Pain improved significantly from 8.7 ± 0.9 to 2.3 ± 1.2 (p < 0.001). Implant radiographic survivorship was 84.6 %. Scapular notching was detected in 7/36 patients (17.5 %). There were five complications: one (stiffness) among patients with fracture sequelae and four among those with failed HH (instability, n = 2; humeral component disassembly, n = 1; pain, n = 1). The two groups did not exhibit significant differences in pain, clinical scores or ROM. Discussion: RTSA with an all-polyethylene glenosphere may have the potential to reduce the risk of biological notching due to polyethylene osteolysis. Further long-term studies are required to assess its efficacy. Conclusions: The good clinical performance and reasonable rate of notching of the polyethylene glenosphere support its use in primary and revision shoulder arthroplasty. Level of evidence: Level 4, retrospective therapeutic case series.

Early clinical and radiological outcomes of reverse shoulder arthroplasty with an eccentric all-polyethylene glenosphere to treat failed hemiarthroplasty and the sequelae of proximal humeral fractures / Merolla, Giovanni; Tartarone, Antonio; Sperling, John W.; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe. - In: INTERNATIONAL ORTHOPAEDICS. - ISSN 0341-2695. - 41:1(2017), pp. 141-148. [10.1007/s00264-016-3188-1]

Early clinical and radiological outcomes of reverse shoulder arthroplasty with an eccentric all-polyethylene glenosphere to treat failed hemiarthroplasty and the sequelae of proximal humeral fractures

Porcellini, Giuseppe
2017

Abstract

Purpose: The aim of this study was to assess the effectiveness of reverse total shoulder arthroplasty (RTSA) with an all-polyethylene glenosphere in patients with failed hemiarthroplasty (HH) or the sequelae of proximal humeral fractures. Methods: Thirty-six patients were assessed at a mean follow-up of 36 months using clinical scores and recording shoulder range of movement (ROM). Results: Active anterior elevation (p < 0.001), lateral elevation (p < 0.001) and internal rotation (p < 0.0001) improved significantly, whereas improvement in external rotation was not significant. The mean Constant score rose significantly from 8.5 ± 7.6 to 40.7 ± 15.7 (p < 0.001) and the Simple Shoulder Test score from 0.42 ± 0.85 to 5.5 ± 2.6 (p < 0.001). Pain improved significantly from 8.7 ± 0.9 to 2.3 ± 1.2 (p < 0.001). Implant radiographic survivorship was 84.6 %. Scapular notching was detected in 7/36 patients (17.5 %). There were five complications: one (stiffness) among patients with fracture sequelae and four among those with failed HH (instability, n = 2; humeral component disassembly, n = 1; pain, n = 1). The two groups did not exhibit significant differences in pain, clinical scores or ROM. Discussion: RTSA with an all-polyethylene glenosphere may have the potential to reduce the risk of biological notching due to polyethylene osteolysis. Further long-term studies are required to assess its efficacy. Conclusions: The good clinical performance and reasonable rate of notching of the polyethylene glenosphere support its use in primary and revision shoulder arthroplasty. Level of evidence: Level 4, retrospective therapeutic case series.
2017
25-apr-2016
41
1
141
148
Early clinical and radiological outcomes of reverse shoulder arthroplasty with an eccentric all-polyethylene glenosphere to treat failed hemiarthroplasty and the sequelae of proximal humeral fractures / Merolla, Giovanni; Tartarone, Antonio; Sperling, John W.; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe. - In: INTERNATIONAL ORTHOPAEDICS. - ISSN 0341-2695. - 41:1(2017), pp. 141-148. [10.1007/s00264-016-3188-1]
Merolla, Giovanni; Tartarone, Antonio; Sperling, John W.; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe
File in questo prodotto:
File Dimensione Formato  
Merolla2017_Article_EarlyClinicalAndRadiologicalOu.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1160394
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 11
social impact