A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion selection by a factor 100 in the momentum range between 15 and 35 GeV/c. The detector consists of a 17 m long tank (vessel), filled with neon gas at atmospheric pressure. Cherenkov light is reflected by a mosaic of 20 spherical mirrors with 17 m focal length, placed at the downstream end, and collected by 1952 photomultipliers (PMTs) placed at the upstream end. In this paper the characterization of the mirrors before installation and the mirror support system are described. The mirror installation procedure and the laser alignment are also illustrated.

Mirror system of the RICH detector of the NA62 experiment / Aisa, D.; Anzivino, G.; Barbanera, M.; Bizzarri, M.; Bizzeti, A.; Bucci, F.; Campeggi, C.; Carassiti, V.; Cassese, A.; Cenci, P.; Ciaranfi, R.; David, C.; Duk, V.; Iacopini, E.; Imbergamo, E.; Latino, G.; Lenti, M.; Lollini, R.; Maletta, F.; Pepe, M.; Piccini, M.; Piluso, A.; Schneider, T.; Scolieri, G.; Van Stenis, M.; Volpe, R.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 12:12(2017), pp. P12017-P12017. [10.1088/1748-0221/12/12/P12017]

Mirror system of the RICH detector of the NA62 experiment

Bizzeti, A.;
2017

Abstract

A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion selection by a factor 100 in the momentum range between 15 and 35 GeV/c. The detector consists of a 17 m long tank (vessel), filled with neon gas at atmospheric pressure. Cherenkov light is reflected by a mosaic of 20 spherical mirrors with 17 m focal length, placed at the downstream end, and collected by 1952 photomultipliers (PMTs) placed at the upstream end. In this paper the characterization of the mirrors before installation and the mirror support system are described. The mirror installation procedure and the laser alignment are also illustrated.
2017
12
12
P12017
P12017
Mirror system of the RICH detector of the NA62 experiment / Aisa, D.; Anzivino, G.; Barbanera, M.; Bizzarri, M.; Bizzeti, A.; Bucci, F.; Campeggi, C.; Carassiti, V.; Cassese, A.; Cenci, P.; Ciaranfi, R.; David, C.; Duk, V.; Iacopini, E.; Imbergamo, E.; Latino, G.; Lenti, M.; Lollini, R.; Maletta, F.; Pepe, M.; Piccini, M.; Piluso, A.; Schneider, T.; Scolieri, G.; Van Stenis, M.; Volpe, R.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 12:12(2017), pp. P12017-P12017. [10.1088/1748-0221/12/12/P12017]
Aisa, D.; Anzivino, G.; Barbanera, M.; Bizzarri, M.; Bizzeti, A.; Bucci, F.; Campeggi, C.; Carassiti, V.; Cassese, A.; Cenci, P.; Ciaranfi, R.; David, C.; Duk, V.; Iacopini, E.; Imbergamo, E.; Latino, G.; Lenti, M.; Lollini, R.; Maletta, F.; Pepe, M.; Piccini, M.; Piluso, A.; Schneider, T.; Scolieri, G.; Van Stenis, M.; Volpe, R.
File in questo prodotto:
File Dimensione Formato  
2017_jinst._12_P12017_mirror_system.pdf

Open access

Descrizione: Articolo pubblicato
Tipologia: Versione pubblicata dall'editore
Dimensione 6.42 MB
Formato Adobe PDF
6.42 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1156291
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 10
social impact