The aim of this survey, promoted by the European Society of Thoracic Surgeons, was to acquire information and advice from 'the field' in order to promote development of technology for thoracic surgery and to provide information for future guidelines on chest drainage. Society members were offered a questionnaire on the European Society of Thoracic Surgeons website (November 2006) composed of seven sections comprehending 21 detailed items. The questionnaire was completed by 120 centres, 100% performed lung surgery, 91.6% mediastinal surgery, 54.1% oesophageal surgery, 10% cardiothoracic surgery. The PVC straight drain (mean 55.9%) and silicon drain (mean 38.4%), water-valve/water suction disposable chest drainage collection system (mean 43.4%), one bottle (mean 24.8%), and two bottles with suction control (mean 18.2%), were the most frequently used. After pneumonectomy 51.2% used a balanced drainage system, 9% periodical thoracocentesis, 39.8% others. In 57.5-92% drainage suction was stopped 4 postoperative days. In 17.6-60.7% drains were removed 4 postoperative days. The survey demonstrates a trend toward the use of updated technical devices, high consideration of the costs, and clinical practice based on personal preferences.
Survey on chest drainage systems adopted in Europe / Mattioli, S; Berrisford, Rg; Lugaresi, Ml; Aramini, B.. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9293. - 7:6(2008), pp. 1155-1159. [10.1510/icvts.2008.181750]
Survey on chest drainage systems adopted in Europe.
Aramini B.Supervision
2008
Abstract
The aim of this survey, promoted by the European Society of Thoracic Surgeons, was to acquire information and advice from 'the field' in order to promote development of technology for thoracic surgery and to provide information for future guidelines on chest drainage. Society members were offered a questionnaire on the European Society of Thoracic Surgeons website (November 2006) composed of seven sections comprehending 21 detailed items. The questionnaire was completed by 120 centres, 100% performed lung surgery, 91.6% mediastinal surgery, 54.1% oesophageal surgery, 10% cardiothoracic surgery. The PVC straight drain (mean 55.9%) and silicon drain (mean 38.4%), water-valve/water suction disposable chest drainage collection system (mean 43.4%), one bottle (mean 24.8%), and two bottles with suction control (mean 18.2%), were the most frequently used. After pneumonectomy 51.2% used a balanced drainage system, 9% periodical thoracocentesis, 39.8% others. In 57.5-92% drainage suction was stopped 4 postoperative days. In 17.6-60.7% drains were removed 4 postoperative days. The survey demonstrates a trend toward the use of updated technical devices, high consideration of the costs, and clinical practice based on personal preferences.File | Dimensione | Formato | |
---|---|---|---|
Sandro Mattioli 2008.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
594.1 kB
Formato
Adobe PDF
|
594.1 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris