In this work, we demonstrate the ultrasensitive and selective detection of dopamine by means of a neuro-inspired device platform without the need of a specific recognition moiety. The sensor is a whole organic device featuring two electrodes made of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate - PEDOT:PSS - patterned on a polydymethylsiloxane - PDMS - flexible substrate. One electrode is pulsed with a train of voltage square waves, to mimic the presynaptic neuron behavior, while the other is used to record the displacement current, mimicking the postsynaptic neuron. The current response exhibits the features of synaptic Short-Term Plasticity (STP) with facilitating or depressing response according to the stimulus frequency. We found that the response characteristic time USTPdepends on dopamine (DA) concentration in solution. The dose curve exhibits superexponential sensitivity at the lowest concentrations below 1 nM. The sensor detects [DA] down to 1 pM range. We assess the sensor also in the presence of ascorbic acid (AA) and uric acid (UA). Our sensor does not respond to UA, but responds to AA only at concentration above 100 μM. However, it is still able to detect DA down to 1 pM range in the presence of [AA] = 100 μM and 100 pM in the presence of [UA] = 3 μM, these values for AA and UA being the physiological levels in the cerebrospinal fluid and the striatum, respectively.
Specific Dopamine Sensing Based on Short-Term Plasticity Behavior of a Whole Organic Artificial Synapse / Giordani, Martina; Berto, Marcello; Di Lauro, Michele; Bortolotti, Carlo A.; Zoli, Michele; Biscarini, Fabio. - In: ACS SENSORS. - ISSN 2379-3694. - 2:12(2017), pp. 1756-1760. [10.1021/acssensors.7b00542]
Specific Dopamine Sensing Based on Short-Term Plasticity Behavior of a Whole Organic Artificial Synapse
Giordani, Martina;Berto, Marcello;Di Lauro, Michele;Bortolotti, Carlo A.;Zoli, Michele;Biscarini, Fabio
2017
Abstract
In this work, we demonstrate the ultrasensitive and selective detection of dopamine by means of a neuro-inspired device platform without the need of a specific recognition moiety. The sensor is a whole organic device featuring two electrodes made of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate - PEDOT:PSS - patterned on a polydymethylsiloxane - PDMS - flexible substrate. One electrode is pulsed with a train of voltage square waves, to mimic the presynaptic neuron behavior, while the other is used to record the displacement current, mimicking the postsynaptic neuron. The current response exhibits the features of synaptic Short-Term Plasticity (STP) with facilitating or depressing response according to the stimulus frequency. We found that the response characteristic time USTPdepends on dopamine (DA) concentration in solution. The dose curve exhibits superexponential sensitivity at the lowest concentrations below 1 nM. The sensor detects [DA] down to 1 pM range. We assess the sensor also in the presence of ascorbic acid (AA) and uric acid (UA). Our sensor does not respond to UA, but responds to AA only at concentration above 100 μM. However, it is still able to detect DA down to 1 pM range in the presence of [AA] = 100 μM and 100 pM in the presence of [UA] = 3 μM, these values for AA and UA being the physiological levels in the cerebrospinal fluid and the striatum, respectively.File | Dimensione | Formato | |
---|---|---|---|
senza_titolo.pdf
Accesso riservato
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
2.24 MB
Formato
Adobe PDF
|
2.24 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris