Commodity HardWare (CHW) is currently used in the Internet to deploy large data centers or small computing nodes. Moreover, CHW will be also used to deploy future telecommunication networks, thanks to the adoption of the forthcoming network softwarization paradigm. In this context, CHW machines can be put in Active Mode (AM) or in Sleep Mode (SM) several times per day, based on the traffic requirements from users. However, the transitions between the power states may introduce fatigue effects, which may increase the CHW maintenance costs. In this paper, we perform a measurement campaign of a CHW machine subject to power state changes introduced by SM. Our results show that the temperature change due to power state transitions is not negligible, and that the abrupt stopping of the fans on hot components (such as the CPU) tends to spread the heat over the other components of the CHW machine. In addition, we also show that the CHW failure rate is reduced by a factor of 5 when the number of transitions between AM and SM states is more than 20 per day and the SM duration is around 800 [s].
A measurement-based analysis of temperature variations introduced by power management on Commodity HardWare / Chiaraviglio, Luca; Blefari-Melazzi, Nicola; Canali, Claudia; Cuomo, Francesca; Lancellotti, Riccardo; Shojafar, Mohammad. - (2017), pp. 1-4. (Intervento presentato al convegno 19th International Conference on Transparent Optical Networks, ICTON 2017 tenutosi a esp nel 2017) [10.1109/ICTON.2017.8025001].
A measurement-based analysis of temperature variations introduced by power management on Commodity HardWare
Canali, Claudia;Lancellotti, Riccardo;Shojafar, Mohammad
2017
Abstract
Commodity HardWare (CHW) is currently used in the Internet to deploy large data centers or small computing nodes. Moreover, CHW will be also used to deploy future telecommunication networks, thanks to the adoption of the forthcoming network softwarization paradigm. In this context, CHW machines can be put in Active Mode (AM) or in Sleep Mode (SM) several times per day, based on the traffic requirements from users. However, the transitions between the power states may introduce fatigue effects, which may increase the CHW maintenance costs. In this paper, we perform a measurement campaign of a CHW machine subject to power state changes introduced by SM. Our results show that the temperature change due to power state transitions is not negligible, and that the abrupt stopping of the fans on hot components (such as the CPU) tends to spread the heat over the other components of the CHW machine. In addition, we also show that the CHW failure rate is reduced by a factor of 5 when the number of transitions between AM and SM states is more than 20 per day and the SM duration is around 800 [s].File | Dimensione | Formato | |
---|---|---|---|
08025001.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
324.62 kB
Formato
Adobe PDF
|
324.62 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris