To improve reliability some systems adopt double redundancy; however, some failure conditions may prevent the normal operation of the machine or the machine to reach a safe state. The method proposed in this paper allows the normal operation of the system even in a fault condition of the control unit. The signals resulting from the parallel execution of code are modulated to a higher frequency and decoupled from each control stage using two capacitors; the information is then demodulated to obtain the control signal, either in the case of one or two branches working in the control unit. © 2014 WIT Press.
Fault tolerant PWM generation with doubleredundant logic / Troni, F.; Concari, C.; Toscani, A.; Buticchi, G.; Franceschini, G.. - 87:(2014), pp. 495-502. (Intervento presentato al convegno 2013 3rd International Conference on Advanced Materials and Information Technology Processing, AMITP 2013 tenutosi a Los Angeles, CA; United States nel October 2013 through 2 October 2013) [10.2495/AMITP20130581].
Fault tolerant PWM generation with doubleredundant logic
Franceschini, G.
2014
Abstract
To improve reliability some systems adopt double redundancy; however, some failure conditions may prevent the normal operation of the machine or the machine to reach a safe state. The method proposed in this paper allows the normal operation of the system even in a fault condition of the control unit. The signals resulting from the parallel execution of code are modulated to a higher frequency and decoupled from each control stage using two capacitors; the information is then demodulated to obtain the control signal, either in the case of one or two branches working in the control unit. © 2014 WIT Press.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris