This paper investigates the effect of different asymmetries on the results of the usual self-commissioning procedures for induction drives, as well as the further possibilities given by a digitally controlled inverter. It is shown that, even at a standstill, it is possible to detect some fault conditions of the machine. In particular, a specific supply scheme is proposed that, through the machine response, allows outlining the rotor conditions. This technique implements the IEEE Standards single-phase rotor test on a DSP-controlled converter, allowing the detection and the quantification of the rotor fault conditions. © 2010 IEEE.

Induction drive health assessment in DSP-based self-commissioning procedures / Concari, Carlo; Franceschini, Giovanni; Tassoni, Carla. - In: IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS. - ISSN 0278-0046. - 58:5(2011), pp. 1490-1500. [10.1109/TIE.2010.2084976]

Induction drive health assessment in DSP-based self-commissioning procedures

Franceschini, Giovanni;
2011

Abstract

This paper investigates the effect of different asymmetries on the results of the usual self-commissioning procedures for induction drives, as well as the further possibilities given by a digitally controlled inverter. It is shown that, even at a standstill, it is possible to detect some fault conditions of the machine. In particular, a specific supply scheme is proposed that, through the machine response, allows outlining the rotor conditions. This technique implements the IEEE Standards single-phase rotor test on a DSP-controlled converter, allowing the detection and the quantification of the rotor fault conditions. © 2010 IEEE.
2011
no
Inglese
58
5
1490
1500
AC machines; automatic test equipment; fault diagnosis; induction motor drives; inverters; magnetic anisotropy; modeling; parameter estimation; Control and Systems Engineering; Computer Science Applications1707 Computer Vision and Pattern Recognition; Electrical and Electronic Engineering
none
info:eu-repo/semantics/article
Contributo su RIVISTA::Articolo su rivista
262
Induction drive health assessment in DSP-based self-commissioning procedures / Concari, Carlo; Franceschini, Giovanni; Tassoni, Carla. - In: IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS. - ISSN 0278-0046. - 58:5(2011), pp. 1490-1500. [10.1109/TIE.2010.2084976]
Concari, Carlo; Franceschini, Giovanni; Tassoni, Carla
3
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1150689
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact