Background Atrial tachyarrhythmias (AT/AF) have been associated with an increased risk of mortality, morbidity and ischemic stroke. Up to now, single chamber ICD diagnostics was not able to detect AT/AF, therefore the incidence of new onset AT/AF in patients with single chamber ICD is not known. Objective To evaluate incidence and predictors of AT/AF occurrence in patients with dual-chamber ICD with no pacing indications and no history of AT/AF that strictly mimic single chamber ICD recipient. Methods & results Consecutive dual-chamber ICD patients were prospectively followed by 47 Italian cardiologic centers in an observational research. Clinical and device data were reviewed by expert cardiologists to assess AT/AF occurrence. Multivariate regression analysis evaluated the risk of new-onset AT/AF and its association with patients’ baseline characteristics and with CHADS2 score. 428 (13.4% female, 64 years old) patients were followed for a median observation period of 31 months. AT/AF episodes occurred in 160 (37.4%) patients when considering at least 5 min duration, in 95 (22.2%) for AT/AF ≥ 6 h, in 47 (11.0%) for AT/AF ≥ 1 day, in 29 (6.8%) for AT/AF ≥ 7 days. Patients with CHADS2 ≥ 2, who comprised 36% of the whole population, showed higher incidence of AT/AF ≥ 6 h compared with patients with CHADS2 < 2 (Hazard Ratio = 1.69, 95% Confidence Interval = 1.13–2.53, p = 0.011). Conclusions Our observations in a population of dual-chamber ICD patients with no pacing indications and no history of AT/AF, who strictly mimic single–chamber ICD recipients, highlight that AT/AF episodes occurred in the 37.5% of the population and CHADS2 score is predictive of new-onset AT/AF.

Can we predict new AF occurrence in single-chamber ICD patients? Insights from an observational investigation / Biffi, Mauro; Ziacchi, Matteo; Ricci, Renato Pietro; Facchin, Domenico; Morani, Giovanni; Landolina, Maurizio; Lunati, Maurizio; Iacopino, Saverio; Capucci, Alessandro; Bianchi, Stefano; Infusino, Tommaso; Botto, Giovanni Luca; Padeletti, Luigi; Boriani, Giuseppe. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 230:(2017), pp. 275-280. [10.1016/j.ijcard.2016.12.126]

Can we predict new AF occurrence in single-chamber ICD patients? Insights from an observational investigation

BORIANI, Giuseppe
2017

Abstract

Background Atrial tachyarrhythmias (AT/AF) have been associated with an increased risk of mortality, morbidity and ischemic stroke. Up to now, single chamber ICD diagnostics was not able to detect AT/AF, therefore the incidence of new onset AT/AF in patients with single chamber ICD is not known. Objective To evaluate incidence and predictors of AT/AF occurrence in patients with dual-chamber ICD with no pacing indications and no history of AT/AF that strictly mimic single chamber ICD recipient. Methods & results Consecutive dual-chamber ICD patients were prospectively followed by 47 Italian cardiologic centers in an observational research. Clinical and device data were reviewed by expert cardiologists to assess AT/AF occurrence. Multivariate regression analysis evaluated the risk of new-onset AT/AF and its association with patients’ baseline characteristics and with CHADS2 score. 428 (13.4% female, 64 years old) patients were followed for a median observation period of 31 months. AT/AF episodes occurred in 160 (37.4%) patients when considering at least 5 min duration, in 95 (22.2%) for AT/AF ≥ 6 h, in 47 (11.0%) for AT/AF ≥ 1 day, in 29 (6.8%) for AT/AF ≥ 7 days. Patients with CHADS2 ≥ 2, who comprised 36% of the whole population, showed higher incidence of AT/AF ≥ 6 h compared with patients with CHADS2 < 2 (Hazard Ratio = 1.69, 95% Confidence Interval = 1.13–2.53, p = 0.011). Conclusions Our observations in a population of dual-chamber ICD patients with no pacing indications and no history of AT/AF, who strictly mimic single–chamber ICD recipients, highlight that AT/AF episodes occurred in the 37.5% of the population and CHADS2 score is predictive of new-onset AT/AF.
2017
22-dic-2016
230
275
280
Can we predict new AF occurrence in single-chamber ICD patients? Insights from an observational investigation / Biffi, Mauro; Ziacchi, Matteo; Ricci, Renato Pietro; Facchin, Domenico; Morani, Giovanni; Landolina, Maurizio; Lunati, Maurizio; Iacopino, Saverio; Capucci, Alessandro; Bianchi, Stefano; Infusino, Tommaso; Botto, Giovanni Luca; Padeletti, Luigi; Boriani, Giuseppe. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 230:(2017), pp. 275-280. [10.1016/j.ijcard.2016.12.126]
Biffi, Mauro; Ziacchi, Matteo; Ricci, Renato Pietro; Facchin, Domenico; Morani, Giovanni; Landolina, Maurizio; Lunati, Maurizio; Iacopino, Saverio; Capucci, Alessandro; Bianchi, Stefano; Infusino, Tommaso; Botto, Giovanni Luca; Padeletti, Luigi; Boriani, Giuseppe
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0167527316346174-main.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 432.25 kB
Formato Adobe PDF
432.25 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1139496
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact