An electrical method to measure extracellular bioelectrical activity in vitro is presented. This method exploits the Helmholtz capacitive double-layer established at the electrode surface. Small extracellular voltage variations in the order of μVs induce through the double-layer capacitor a displacement current that is measured. This current is then enhanced by a gain factor proportional to the electrode capacitance. In addition, when measurements are carried out at low frequencies in current mode the electrode contribution to the noise can be minimized. The performance of the electrodes and the method is demonstrated using zebrafish hearts and glioma cell cultures. We propose that this electrical method is an ideal tool to measure in vitro slow and temporally synchronized events that are often involved in long range intracellular signaling.
An electrical method to measure low-frequency collective and synchronized cell activity using extracellular electrodes / Medeiros, Maria C. R.; Mestre, Ana; Inácio, Pedro; Asgarif, Sanaz; Araújo, Inês M.; Hubbard, Peter C.; Velez, Zélia; Cancela, M. Leonor; Rocha, Paulo R. F.; de Leeuw, Dago M.; Biscarini, Fabio; Gomes, Henrique L.. - In: SENSING AND BIO-SENSING RESEARCH. - ISSN 2214-1804. - 10:(2016), pp. 1-8. [10.1016/j.sbsr.2016.06.002]
An electrical method to measure low-frequency collective and synchronized cell activity using extracellular electrodes
BISCARINI, FABIO;
2016
Abstract
An electrical method to measure extracellular bioelectrical activity in vitro is presented. This method exploits the Helmholtz capacitive double-layer established at the electrode surface. Small extracellular voltage variations in the order of μVs induce through the double-layer capacitor a displacement current that is measured. This current is then enhanced by a gain factor proportional to the electrode capacitance. In addition, when measurements are carried out at low frequencies in current mode the electrode contribution to the noise can be minimized. The performance of the electrodes and the method is demonstrated using zebrafish hearts and glioma cell cultures. We propose that this electrical method is an ideal tool to measure in vitro slow and temporally synchronized events that are often involved in long range intracellular signaling.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S2214180416300654-main.pdf
Open access
Tipologia:
Versione pubblicata dall'editore
Dimensione
927.8 kB
Formato
Adobe PDF
|
927.8 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris