.Two different adaptive predictive controllers are used for controlling the benchmark plant. One is of an indirect type, the other of an implicit type. In both cases, the only a priori knowledge used is that the nominal process order equals three.
Indirect and implicit adaptive predictive control of a benchmark plant / Chisci, L.; Giarrè, Laura; Mosca, E.. - In: AUTOMATICA. - ISSN 0005-1098. - 30:(1994), pp. 577-584. [10.1016/0005-1098(94)90143-0]
Indirect and implicit adaptive predictive control of a benchmark plant
GIARRÈ, Laura;
1994-01-01
Abstract
.Two different adaptive predictive controllers are used for controlling the benchmark plant. One is of an indirect type, the other of an implicit type. In both cases, the only a priori knowledge used is that the nominal process order equals three.File in questo prodotto: