Objective The aim of this study was to assess the association between maximum daily atrial fibrillation (AF) burden and risk of ischaemic stroke. Background Cardiac implanted electronic devices (CIEDs) enhance detection of AF, providing a comprehensive measure of AF burden. Design, setting, and patients A pooled analysis of individual patient data from five prospective studies was performed. Patients without permanent AF, previously implanted with CIEDs, were included if they had at least 3 months of follow-up. A total of 10 016 patients (median age 70 years) met these criteria. The risk of ischaemic stroke associated with pre-specified cut-off points of AF burden (5 min, 1, 6, 12, and 23 h, respectively) was assessed. Results During a median follow-up of 24 months, 43% of 10 016 patients experienced at least 1 day with at least 5 min of AF burden and for them the median time to the maximum AF burden was 6 months (inter-quartile range: 1.3–14). A Cox regression analysis adjusted for the CHADS2 score and anticoagulants at baseline demonstrated that AF burden was an independent predictor of ischaemic stroke. Among the thresholds of AF burden that we evaluated, 1 h was associated with the highest hazard ratio (HR) for ischaemic stroke, i.e. 2.11 (95% CI: 1.22–3.64, P = 0.008). Conclusions Device-detected AF burden is associated with an increased risk of ischaemic stroke in a relatively unselected population of CIEDs patients. This finding may add to the basis for timely and clinically appropriate decision-making on anticoagulation treatment.

Device-detected atrial fibrillation and risk for stroke: An analysis of >10 000 patients from the SOS AF project (Stroke preventiOn Strategies based on Atrial Fibrillation information from implanted devices) / Boriani, Giuseppe; Glotzer, Taya V.; Santini, Massimo; West, Teena M.; De Melis, Mirko; Sepsi, Milan; Gasparini, Maurizio; Lewalter, Thorsten; Camm, John A.; Singer, Daniel E.. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - STAMPA. - 35:(2014), pp. 508-516. [10.1093/eurheartj/eht491]

Device-detected atrial fibrillation and risk for stroke: An analysis of >10 000 patients from the SOS AF project (Stroke preventiOn Strategies based on Atrial Fibrillation information from implanted devices)

BORIANI, Giuseppe;
2014

Abstract

Objective The aim of this study was to assess the association between maximum daily atrial fibrillation (AF) burden and risk of ischaemic stroke. Background Cardiac implanted electronic devices (CIEDs) enhance detection of AF, providing a comprehensive measure of AF burden. Design, setting, and patients A pooled analysis of individual patient data from five prospective studies was performed. Patients without permanent AF, previously implanted with CIEDs, were included if they had at least 3 months of follow-up. A total of 10 016 patients (median age 70 years) met these criteria. The risk of ischaemic stroke associated with pre-specified cut-off points of AF burden (5 min, 1, 6, 12, and 23 h, respectively) was assessed. Results During a median follow-up of 24 months, 43% of 10 016 patients experienced at least 1 day with at least 5 min of AF burden and for them the median time to the maximum AF burden was 6 months (inter-quartile range: 1.3–14). A Cox regression analysis adjusted for the CHADS2 score and anticoagulants at baseline demonstrated that AF burden was an independent predictor of ischaemic stroke. Among the thresholds of AF burden that we evaluated, 1 h was associated with the highest hazard ratio (HR) for ischaemic stroke, i.e. 2.11 (95% CI: 1.22–3.64, P = 0.008). Conclusions Device-detected AF burden is associated with an increased risk of ischaemic stroke in a relatively unselected population of CIEDs patients. This finding may add to the basis for timely and clinically appropriate decision-making on anticoagulation treatment.
2014
35
508
516
Device-detected atrial fibrillation and risk for stroke: An analysis of >10 000 patients from the SOS AF project (Stroke preventiOn Strategies based on Atrial Fibrillation information from implanted devices) / Boriani, Giuseppe; Glotzer, Taya V.; Santini, Massimo; West, Teena M.; De Melis, Mirko; Sepsi, Milan; Gasparini, Maurizio; Lewalter, Thorsten; Camm, John A.; Singer, Daniel E.. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - STAMPA. - 35:(2014), pp. 508-516. [10.1093/eurheartj/eht491]
Boriani, Giuseppe; Glotzer, Taya V.; Santini, Massimo; West, Teena M.; De Melis, Mirko; Sepsi, Milan; Gasparini, Maurizio; Lewalter, Thorsten; Camm, John A.; Singer, Daniel E.
File in questo prodotto:
File Dimensione Formato  
Boriani SOS AF EHJ 2014.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 538.74 kB
Formato Adobe PDF
538.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1081638
Citazioni
  • ???jsp.display-item.citation.pmc??? 108
  • Scopus 331
  • ???jsp.display-item.citation.isi??? 313
social impact