Long road and railway tunnels necessitate of a fine-tuned control of the ventilation system to be activated, for both safety and air quality maintenance reasons. This, in turn, requires that the main fluid-dynamic parameters of the tunnel are known with sufficient accuracy, so that the system behaviour can be predicted with reasonable confidence under standard and emergency operative conditions. As a first step in the modelling of the complex system embodying the 11,611. m long Mont Blanc road tunnel, and its ventilation facilities, a movable 5-point survey rake was designed and built-up, for detecting the distribution of the axial velocity on the tunnel cross-section. Two extensive experimental campaigns were carried out, where the airflow-rates were either measured at different stations along the tunnel length (C1), or at a fixed location, under purely axial main-flow conditions and varying the number of the activated axial fan pairs (C2). A simplified dynamic model of the tunnel was developed, and the airflow data from the experiments were used for the model fine-tuning, additional CFD analyses having provided extra information on concentrated pressure losses connected with air inlet and discharge through the tunnel ends. The Mont Blanc tunnel was finally characterised in terms of friction factors and jet-fans installation efficiency.
Fluid-dynamic characterisation of the Mont Blanc tunnel by multi-point airflow measurements / Levoni, Paolo; Angeli, Diego; Stalio, Enrico; Agnani, Elia; Barozzi, Giovanni Sebastiano; Cipollone, M.. - In: TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY. - ISSN 0886-7798. - 48:(2015), pp. 110-122. [10.1016/j.tust.2015.03.006]
Fluid-dynamic characterisation of the Mont Blanc tunnel by multi-point airflow measurements
LEVONI, Paolo;ANGELI, Diego;STALIO, Enrico;AGNANI, ELIA;BAROZZI, Giovanni Sebastiano;
2015
Abstract
Long road and railway tunnels necessitate of a fine-tuned control of the ventilation system to be activated, for both safety and air quality maintenance reasons. This, in turn, requires that the main fluid-dynamic parameters of the tunnel are known with sufficient accuracy, so that the system behaviour can be predicted with reasonable confidence under standard and emergency operative conditions. As a first step in the modelling of the complex system embodying the 11,611. m long Mont Blanc road tunnel, and its ventilation facilities, a movable 5-point survey rake was designed and built-up, for detecting the distribution of the axial velocity on the tunnel cross-section. Two extensive experimental campaigns were carried out, where the airflow-rates were either measured at different stations along the tunnel length (C1), or at a fixed location, under purely axial main-flow conditions and varying the number of the activated axial fan pairs (C2). A simplified dynamic model of the tunnel was developed, and the airflow data from the experiments were used for the model fine-tuning, additional CFD analyses having provided extra information on concentrated pressure losses connected with air inlet and discharge through the tunnel ends. The Mont Blanc tunnel was finally characterised in terms of friction factors and jet-fans installation efficiency.File | Dimensione | Formato | |
---|---|---|---|
TUST_Levoni_et_al.pdf
Accesso riservato
Descrizione: Articolo
Tipologia:
Versione pubblicata dall'editore
Dimensione
2.63 MB
Formato
Adobe PDF
|
2.63 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris