BACKGROUND: A multicenter European Registry, SEARCH-MI, was instituted in the year 2002 in order to assess patients' outcomes and ICD interventions in patients with a previous MI and depressed LV function, treated with an ICD according to MADIT II results. In this analysis, we evaluate the influence of the time elapsed between last myocardial infarction (MI) and prophylactic cardioverter defibrillator (ICD) implant on device activations. METHODS: 643 patients with left ventricular dysfunction (mean LVEF 26 ± 5%) and NYHA class I-III were prospectively followed for 1.8 ± 1.2 years in a multicenter registry. The population was divided into 3 groups according to the time between last MI and ICD implant: [1] from 40 days to less than 1.5 years; [2] from 1.5 to less than 7 years and [3] at least 7 years. RESULTS: The cumulative incidence of ventricular tachyarrhymias and appropriate device therapy (ATP or shock) were higher in patients implanted longer time from last MI (Gray's Test p=0.002 and p=0.013 respectively). No significant differences were seen in all cause mortality (Gray's Test p=0.618) or sudden cardiac death across the MI stratification groups (Gray's Test p=0.663). CONCLUSIONS: Patients implanted with an ICD longer after the MI have a higher chance of presenting ventricular tachyarrhythmias and appropriate ICD therapy, while no differences were seen in overall mortality. These observations may be important for improving patient targeting in sudden death prevention.

Influence of time between last myocardial infarction and prophylactic implantable defibrillator implant on device detections and therapies. Routine Practice data from the SEARCH MI registry / Boriani, Giuseppe; Botto, G; Lunati, M; Proclemer, A; Schmidt, B; Erdogan, A; Rauhe, W; Biffi, M; Santi, E; Becker, D; Messier, M; Santini, M.. - In: BMC CARDIOVASCULAR DISORDERS. - ISSN 1471-2261. - 12:72(2012), pp. 1-7. [10.1186/1471-2261-12-72]

Influence of time between last myocardial infarction and prophylactic implantable defibrillator implant on device detections and therapies. Routine Practice data from the SEARCH MI registry.

BORIANI, Giuseppe;
2012

Abstract

BACKGROUND: A multicenter European Registry, SEARCH-MI, was instituted in the year 2002 in order to assess patients' outcomes and ICD interventions in patients with a previous MI and depressed LV function, treated with an ICD according to MADIT II results. In this analysis, we evaluate the influence of the time elapsed between last myocardial infarction (MI) and prophylactic cardioverter defibrillator (ICD) implant on device activations. METHODS: 643 patients with left ventricular dysfunction (mean LVEF 26 ± 5%) and NYHA class I-III were prospectively followed for 1.8 ± 1.2 years in a multicenter registry. The population was divided into 3 groups according to the time between last MI and ICD implant: [1] from 40 days to less than 1.5 years; [2] from 1.5 to less than 7 years and [3] at least 7 years. RESULTS: The cumulative incidence of ventricular tachyarrhymias and appropriate device therapy (ATP or shock) were higher in patients implanted longer time from last MI (Gray's Test p=0.002 and p=0.013 respectively). No significant differences were seen in all cause mortality (Gray's Test p=0.618) or sudden cardiac death across the MI stratification groups (Gray's Test p=0.663). CONCLUSIONS: Patients implanted with an ICD longer after the MI have a higher chance of presenting ventricular tachyarrhythmias and appropriate ICD therapy, while no differences were seen in overall mortality. These observations may be important for improving patient targeting in sudden death prevention.
2012
12
72
1
7
Influence of time between last myocardial infarction and prophylactic implantable defibrillator implant on device detections and therapies. Routine Practice data from the SEARCH MI registry / Boriani, Giuseppe; Botto, G; Lunati, M; Proclemer, A; Schmidt, B; Erdogan, A; Rauhe, W; Biffi, M; Santi, E; Becker, D; Messier, M; Santini, M.. - In: BMC CARDIOVASCULAR DISORDERS. - ISSN 1471-2261. - 12:72(2012), pp. 1-7. [10.1186/1471-2261-12-72]
Boriani, Giuseppe; Botto, G; Lunati, M; Proclemer, A; Schmidt, B; Erdogan, A; Rauhe, W; Biffi, M; Santi, E; Becker, D; Messier, M; Santini, M.
File in questo prodotto:
File Dimensione Formato  
1471-2261-12-72.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 503.11 kB
Formato Adobe PDF
503.11 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1080303
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact