Abstract We assessed the influence of clinically significant mitral regurgitation (MR) on clinical-echocardiographic response and outcome in heart failure (HF) patients treated with a biventricular defibrillator (cardiac resynchronization therapy defibrillator [CRT-D]). METHODS AND RESULTS: A total of 659 HF patients underwent successful implantation of CRT-D and were enrolled in a multicenter prospective registry (median follow-up of 15 months). Following baseline echocardiographic evaluation, patients were stratified into two groups according to the severity of MR: 232 patients with more than mild MR (Group MR+: grade 2, 3, and 4 MR) versus 427 patients with mild (grade 1) or no functional MR (Group MR-). On 6- and 12-month echocardiographic evaluation, MR was seen to have improved in the vast majority of MR+ patients, while it remained unchanged in most MR- patients. On 12-month follow-up evaluation, a comparable response to CRT was observed in the two groups, in terms of the extent of left ventricular reverse remodeling and combined clinical and echocardiographic response. During long-term follow-up, event-free survival did not differ between MR+ and MR- patients, even when subpopulations of patients with ischemic heart disease and with dilated cardiomyopathy were analyzed separately. On multivariate analysis, the only independent predictor of death from any cause was the lack of β-blocker use. CONCLUSIONS: This observational analysis supports the use of CRT-D in HF patients with clinically significant MR; MR had no major influence on patient outcome.

Impact of mitral regurgitation on the outcome of patients treated with CRT-D: data from the InSync ICD Italian Registry / Boriani, Giuseppe; Gasparini, M; Landolina, M; Lunati, M; Biffi, M; Santini, M; Padeletti, L; Molon, G; Botto, G; de Santo, T; Valsecchi, S; InSync/InSync ICD Italian Registry, Investigators. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 35:2(2012), pp. 146-154. [10.1111/j.1540-8159.2011.03280.x]

Impact of mitral regurgitation on the outcome of patients treated with CRT-D: data from the InSync ICD Italian Registry.

BORIANI, Giuseppe;
2012

Abstract

Abstract We assessed the influence of clinically significant mitral regurgitation (MR) on clinical-echocardiographic response and outcome in heart failure (HF) patients treated with a biventricular defibrillator (cardiac resynchronization therapy defibrillator [CRT-D]). METHODS AND RESULTS: A total of 659 HF patients underwent successful implantation of CRT-D and were enrolled in a multicenter prospective registry (median follow-up of 15 months). Following baseline echocardiographic evaluation, patients were stratified into two groups according to the severity of MR: 232 patients with more than mild MR (Group MR+: grade 2, 3, and 4 MR) versus 427 patients with mild (grade 1) or no functional MR (Group MR-). On 6- and 12-month echocardiographic evaluation, MR was seen to have improved in the vast majority of MR+ patients, while it remained unchanged in most MR- patients. On 12-month follow-up evaluation, a comparable response to CRT was observed in the two groups, in terms of the extent of left ventricular reverse remodeling and combined clinical and echocardiographic response. During long-term follow-up, event-free survival did not differ between MR+ and MR- patients, even when subpopulations of patients with ischemic heart disease and with dilated cardiomyopathy were analyzed separately. On multivariate analysis, the only independent predictor of death from any cause was the lack of β-blocker use. CONCLUSIONS: This observational analysis supports the use of CRT-D in HF patients with clinically significant MR; MR had no major influence on patient outcome.
2012
35
2
146
154
Impact of mitral regurgitation on the outcome of patients treated with CRT-D: data from the InSync ICD Italian Registry / Boriani, Giuseppe; Gasparini, M; Landolina, M; Lunati, M; Biffi, M; Santini, M; Padeletti, L; Molon, G; Botto, G; de Santo, T; Valsecchi, S; InSync/InSync ICD Italian Registry, Investigators. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 35:2(2012), pp. 146-154. [10.1111/j.1540-8159.2011.03280.x]
Boriani, Giuseppe; Gasparini, M; Landolina, M; Lunati, M; Biffi, M; Santini, M; Padeletti, L; Molon, G; Botto, G; de Santo, T; Valsecchi, S; InSync/InSync ICD Italian Registry, Investigators
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1080295
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 15
social impact