Predictors of ATP efficacy in brady/tachy patients. BACKGROUND: Recent options to treat atrial tachyarrhythmias (ATA) include implantable devices delivering antitachycardia pacing therapies (ATP). No prospective study selected patients with higher chances of episode termination by ATP or indicated the most effective ATP use. Our aim was to study ATP efficacy in patients with brady-tachy form of sinus node disease (SND), identifying clinical factors, ATA characteristics, and device features predicting ATP efficacy. METHODS AND RESULTS: Three hundred and sixteen patients (105 M, aged 71.1+/-8.8 years) received a DDDRP pacemaker and were prospectively followed. Median follow-up was 18 months: 37,125 ATA episodes occurred in 217 patients; ATP treated 5,536 of them. Overall, ATP efficacy was 50.0%. A multivariate analysis identified longer arrhythmia cycle lengths (OR=1.25; CI=1.07-1.47) and shorter delays to ATP delivery (OR=0.15; CI=0.10-0.22) as independent predictors of ATP efficacy for episodes preceded by >or=5 minutes of sinus rhythm. Additionally, ATP efficacy for all treated episodes was predicted by lower New York Heart Association (NYHA) class (OR=0.64; CI=0.42-0.98), episode classification as nonimmediate recurrence of ATA (non-IRAT) (OR=0.07; CI=0.02-0.33), absence of overlap in the device detection windows (OR=0.54; CI=0.32-0.91), and flecainide treatment (OR=2.22; CI=1.04-4.71). CONCLUSIONS: In patients paced for SND, multivariate analysis shows that ATP efficacy is associated to longer arrhythmia cycle lengths, shorter ATP delivery delays, NYHA class I, episode classification as non-IRAT, absence of overlap in the atrial arrhythmia device detection windows, and flecainide treatment.

Predictors of atrial antitachycardia pacing efficacy in patients affected by brady-tachy form of sick sinus syndrome and implanted with a DDDRP device / Boriani, Giuseppe; Padeletti, L; Santini, M; Gulizia, M; Capucci, A; Botto, G; Ricci, R; Molon, G; Accogli, M; Vicentini, A; Biffi, M; Vimercati, M; Grammatico, A.. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - 16:7(2005), pp. 714-723. [10.1111/j.1540-8167.2005.40716.x]

Predictors of atrial antitachycardia pacing efficacy in patients affected by brady-tachy form of sick sinus syndrome and implanted with a DDDRP device.

BORIANI, Giuseppe;
2005

Abstract

Predictors of ATP efficacy in brady/tachy patients. BACKGROUND: Recent options to treat atrial tachyarrhythmias (ATA) include implantable devices delivering antitachycardia pacing therapies (ATP). No prospective study selected patients with higher chances of episode termination by ATP or indicated the most effective ATP use. Our aim was to study ATP efficacy in patients with brady-tachy form of sinus node disease (SND), identifying clinical factors, ATA characteristics, and device features predicting ATP efficacy. METHODS AND RESULTS: Three hundred and sixteen patients (105 M, aged 71.1+/-8.8 years) received a DDDRP pacemaker and were prospectively followed. Median follow-up was 18 months: 37,125 ATA episodes occurred in 217 patients; ATP treated 5,536 of them. Overall, ATP efficacy was 50.0%. A multivariate analysis identified longer arrhythmia cycle lengths (OR=1.25; CI=1.07-1.47) and shorter delays to ATP delivery (OR=0.15; CI=0.10-0.22) as independent predictors of ATP efficacy for episodes preceded by >or=5 minutes of sinus rhythm. Additionally, ATP efficacy for all treated episodes was predicted by lower New York Heart Association (NYHA) class (OR=0.64; CI=0.42-0.98), episode classification as nonimmediate recurrence of ATA (non-IRAT) (OR=0.07; CI=0.02-0.33), absence of overlap in the device detection windows (OR=0.54; CI=0.32-0.91), and flecainide treatment (OR=2.22; CI=1.04-4.71). CONCLUSIONS: In patients paced for SND, multivariate analysis shows that ATP efficacy is associated to longer arrhythmia cycle lengths, shorter ATP delivery delays, NYHA class I, episode classification as non-IRAT, absence of overlap in the atrial arrhythmia device detection windows, and flecainide treatment.
2005
16
7
714
723
Predictors of atrial antitachycardia pacing efficacy in patients affected by brady-tachy form of sick sinus syndrome and implanted with a DDDRP device / Boriani, Giuseppe; Padeletti, L; Santini, M; Gulizia, M; Capucci, A; Botto, G; Ricci, R; Molon, G; Accogli, M; Vicentini, A; Biffi, M; Vimercati, M; Grammatico, A.. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - 16:7(2005), pp. 714-723. [10.1111/j.1540-8167.2005.40716.x]
Boriani, Giuseppe; Padeletti, L; Santini, M; Gulizia, M; Capucci, A; Botto, G; Ricci, R; Molon, G; Accogli, M; Vicentini, A; Biffi, M; Vimercati, M; Grammatico, A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1080256
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 16
social impact