To investigate the efficacy and safety of a cardiac resynchronization therapy with cardioverter-defibrillator (CRT-D) device with simplified ventricular tachycardia management in patients with non-ischaemic heart failure (HF) and primary prevention implantable cardioverter defibrillator (ICD) indication.
A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study / Gasparini, M; Menozzi, C; Proclemer, A; Landolina, M; Iacopino, S; Carboni, A; Lombardo, E; Regoli, F; Biffi, M; Burrone, V; Denaro, A; Boriani, Giuseppe. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - 30:22(2009), pp. 2758-2767.
Data di pubblicazione: | 2009 |
Titolo: | A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study. |
Autore/i: | Gasparini, M; Menozzi, C; Proclemer, A; Landolina, M; Iacopino, S; Carboni, A; Lombardo, E; Regoli, F; Biffi, M; Burrone, V; Denaro, A; Boriani, Giuseppe |
Autore/i UNIMORE: | |
Digital Object Identifier (DOI): | http://dx.doi.org/10.1093/eurheartj/ehp247 |
Rivista: | |
Volume: | 30 |
Fascicolo: | 22 |
Pagina iniziale: | 2758 |
Pagina finale: | 2767 |
Codice identificativo ISI: | WOS:000272066200013 |
Codice identificativo Scopus: | 2-s2.0-72949114097 |
Codice identificativo Pubmed: | 19567380 |
Citazione: | A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study / Gasparini, M; Menozzi, C; Proclemer, A; Landolina, M; Iacopino, S; Carboni, A; Lombardo, E; Regoli, F; Biffi, M; Burrone, V; Denaro, A; Boriani, Giuseppe. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - 30:22(2009), pp. 2758-2767. |