Background: Hypertrophic cardiomyopathy is a genetic disease associated with a risk of ventricular tachyarrhythmias and sudden death, especially in young patients. Methods: We conducted a retrospective multicenter study of the efficacy of implantable cardioverter-defibrillators in preventing sudden death in 128 patients with hypertrophic cardiomyopathy who were judged to be at high risk for sudden death. Results: At the time of the implantation of the defibrillator, the patients were 8 to 82 years old (mean [+/-SD], 40+/-16), and 69 patients (54 percent) were less than 41 years old. The average follow-up period was 3.1 years. Defibrillators were activated appropriately in 29 patients (23 percent), by providing defibrillation shocks or antitachycardia pacing, with the restoration of sinus rhythm; the average age at the time of the intervention was 41 years. The rate of appropriate defibrillator discharge was 7 percent per year. A total of 32 patients (25 percent) had episodes of inappropriate discharges. In the group of 43 patients who received defibrillators for secondary prevention (after cardiac arrest or sustained ventricular tachycardia), the devices were activated appropriately in 19 patients (11 percent per year). Of 85 patients who had prophylactic implants because of risk factors (i.e., for primary prevention), 10 had appropriate interventions (5 percent per year). The interval between implantation and the first appropriate discharge was highly variable but was substantially prolonged (four to nine years) in six patients. In all 21 patients with stored electrographic data and appropriate interventions, the interventions were triggered by ventricular tachycardia or fibrillation. Conclusions: Ventricular tachycardia or fibrillation appears to be the principal mechanism of sudden death in patients with hypertrophic cardiomyopathy. In high-risk patients with hypertrophic cardiomyopathy, implantable defibrillators are highly effective in terminating such arrhythmias, indicating that these devices have a role in the primary and secondary prevention of sudden death. (N Engl J Med 2000;342:365-73.) (C)2000, Massachusetts Medical Society.

Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy / Maron, Bj; Shen, Wk; Link, Ms; Epstein, Ae; Almquist, Ak; Daubert, Jp; Bardy, Gh; Favale, S; Rea, Rf; Boriani, Giuseppe; Estes, Nam; Spirito, P.. - In: THE NEW ENGLAND JOURNAL OF MEDICINE. - ISSN 0028-4793. - 342:6(2000), pp. 365-373. [10.1056/NEJM200002103420601]

Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy.

BORIANI, Giuseppe;
2000

Abstract

Background: Hypertrophic cardiomyopathy is a genetic disease associated with a risk of ventricular tachyarrhythmias and sudden death, especially in young patients. Methods: We conducted a retrospective multicenter study of the efficacy of implantable cardioverter-defibrillators in preventing sudden death in 128 patients with hypertrophic cardiomyopathy who were judged to be at high risk for sudden death. Results: At the time of the implantation of the defibrillator, the patients were 8 to 82 years old (mean [+/-SD], 40+/-16), and 69 patients (54 percent) were less than 41 years old. The average follow-up period was 3.1 years. Defibrillators were activated appropriately in 29 patients (23 percent), by providing defibrillation shocks or antitachycardia pacing, with the restoration of sinus rhythm; the average age at the time of the intervention was 41 years. The rate of appropriate defibrillator discharge was 7 percent per year. A total of 32 patients (25 percent) had episodes of inappropriate discharges. In the group of 43 patients who received defibrillators for secondary prevention (after cardiac arrest or sustained ventricular tachycardia), the devices were activated appropriately in 19 patients (11 percent per year). Of 85 patients who had prophylactic implants because of risk factors (i.e., for primary prevention), 10 had appropriate interventions (5 percent per year). The interval between implantation and the first appropriate discharge was highly variable but was substantially prolonged (four to nine years) in six patients. In all 21 patients with stored electrographic data and appropriate interventions, the interventions were triggered by ventricular tachycardia or fibrillation. Conclusions: Ventricular tachycardia or fibrillation appears to be the principal mechanism of sudden death in patients with hypertrophic cardiomyopathy. In high-risk patients with hypertrophic cardiomyopathy, implantable defibrillators are highly effective in terminating such arrhythmias, indicating that these devices have a role in the primary and secondary prevention of sudden death. (N Engl J Med 2000;342:365-73.) (C)2000, Massachusetts Medical Society.
2000
342
6
365
373
Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy / Maron, Bj; Shen, Wk; Link, Ms; Epstein, Ae; Almquist, Ak; Daubert, Jp; Bardy, Gh; Favale, S; Rea, Rf; Boriani, Giuseppe; Estes, Nam; Spirito, P.. - In: THE NEW ENGLAND JOURNAL OF MEDICINE. - ISSN 0028-4793. - 342:6(2000), pp. 365-373. [10.1056/NEJM200002103420601]
Maron, Bj; Shen, Wk; Link, Ms; Epstein, Ae; Almquist, Ak; Daubert, Jp; Bardy, Gh; Favale, S; Rea, Rf; Boriani, Giuseppe; Estes, Nam; Spirito, P.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1080164
Citazioni
  • ???jsp.display-item.citation.pmc??? 120
  • Scopus 891
  • ???jsp.display-item.citation.isi??? 651
social impact