BACKGROUND: Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at 12-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon for the treatment of distal radius fractures. MATERIALS AND METHODS: We included 40 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the AO classification: 21 fractures were type C1, 9 were type C2, 2 were type C3, 2 were type B1 and 6 were type B2. RESULTS: At a 12-month follow-up no cases of hardware breakage or loss of the surgically achieved fracture reduction were documented. All fractures healed, and radiographic union was observed at an average of 6 weeks. The final Disabilities of Arm, Shoulder and Hand score was 6.0 points. The average grip strength, expressed as a percentage of the contralateral limb, was 92 %. Hardware removal was performed only in one case, for the occurrence of extensor tenosynovitis. CONCLUSION: At early follow-up this device showed good clinical results and allowed maintenance of reduction in complex, AO fractures. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases / Tarallo, Luigi; Mugnai, Raffaele; Adani, Roberto; Zambianchi, Francesco; Catani, Fabio. - In: JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY. - ISSN 1590-9921. - STAMPA. - 15:4(2014), pp. 277-283. [10.1007/s10195-014-0311-1]

A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases

TARALLO, Luigi;Mugnai, Raffaele;Adani, Roberto;Zambianchi, Francesco;CATANI, Fabio
2014

Abstract

BACKGROUND: Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at 12-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon for the treatment of distal radius fractures. MATERIALS AND METHODS: We included 40 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the AO classification: 21 fractures were type C1, 9 were type C2, 2 were type C3, 2 were type B1 and 6 were type B2. RESULTS: At a 12-month follow-up no cases of hardware breakage or loss of the surgically achieved fracture reduction were documented. All fractures healed, and radiographic union was observed at an average of 6 weeks. The final Disabilities of Arm, Shoulder and Hand score was 6.0 points. The average grip strength, expressed as a percentage of the contralateral limb, was 92 %. Hardware removal was performed only in one case, for the occurrence of extensor tenosynovitis. CONCLUSION: At early follow-up this device showed good clinical results and allowed maintenance of reduction in complex, AO fractures. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
2014
15
4
277
283
A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases / Tarallo, Luigi; Mugnai, Raffaele; Adani, Roberto; Zambianchi, Francesco; Catani, Fabio. - In: JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY. - ISSN 1590-9921. - STAMPA. - 15:4(2014), pp. 277-283. [10.1007/s10195-014-0311-1]
Tarallo, Luigi; Mugnai, Raffaele; Adani, Roberto; Zambianchi, Francesco; Catani, Fabio
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs10195-014-0311-1.pdf

Open access

Descrizione: articolo principale
Tipologia: Versione pubblicata dall'editore
Dimensione 685.47 kB
Formato Adobe PDF
685.47 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1079901
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 39
  • ???jsp.display-item.citation.isi??? ND
social impact