Objective: The aim of the study was to verify the existence of a correlation between fluid filtration and tubular penetration of an endodontic sealer. Methods: Ten pairs of maxillary incisors with a single root canal, circular cross-section, similar sizes and dimensions were selected from a collection. Teeth from each pair were randomly divided in 2 groups. All canals were instrumented using NiTi WaveOne Primary instrument (#25) (Dentsply, Maillefer). In the group 1 all canals were irrigated with 1 mL of 5,25% NaOCl for 30s (Ogna, Muggiò, Italy), followed by 0.5 mL of 10% EDTA for 30 s (Ogna). In the group 2 it’s used the same protocol but without the EDTA. A final irrigation of 2.0 mL 5,25% NaOCl for 3m was performed. Root filling was performed with Thermafil-obturators (Dentsply Tulsa, Tulsa, OK) with TopSeal (Dentsply, Maillefer) mixed with 0.1 wt% alizarin to evaluate the penetration depth of the sealer into tubules with confocal microscope (Leica, Wetzlar, Germany). Microleakage i.e. the volume of a calcein solution infiltrated into the root canal and tubules were evaluated using a digital fluid flow-meter and a confocal microscope. Results: Confocal microscopy showed a penetration of the sealer into tubules in group 1 of approx. 370 μm at 3 mm from the apex and 630 μm at 5 mm while in group 2 of approx. 22 μm at 3 mm and 37 μm at 5 mm from the apex. The volume of the infiltrated fluid was 0.353 x 10-4 mm3 for group 1 and 0.397 x 10-4 mm3 for group 2. The data of calcein penetration into the root canal were in agreement with the fluid filtration results. Conclusion: A correlation seems to be present between sealer penetration into dentinal tubules and sealability of Thermafil-obturators and TopSeal in root canal shaped with WaveOne Primary file.

Correlation between Microleakage and Tubules Penetration of an Endodontic Sealer / Gandolfi, Mg; Generali, Luigi; Ferri, A; Pelliccioni, Ga; Consolo, Ugo; Prati, C.. - In: JOURNAL OF DENTAL RESEARCH. - ISSN 0022-0345. - ELETTRONICO. - 92:(2013). (Intervento presentato al convegno Annual Meeting of the IADR Continental European Division (CED) tenutosi a Firenze nel 4-7 settembre 2013).

Correlation between Microleakage and Tubules Penetration of an Endodontic Sealer

GENERALI, Luigi;CONSOLO, Ugo;
2013

Abstract

Objective: The aim of the study was to verify the existence of a correlation between fluid filtration and tubular penetration of an endodontic sealer. Methods: Ten pairs of maxillary incisors with a single root canal, circular cross-section, similar sizes and dimensions were selected from a collection. Teeth from each pair were randomly divided in 2 groups. All canals were instrumented using NiTi WaveOne Primary instrument (#25) (Dentsply, Maillefer). In the group 1 all canals were irrigated with 1 mL of 5,25% NaOCl for 30s (Ogna, Muggiò, Italy), followed by 0.5 mL of 10% EDTA for 30 s (Ogna). In the group 2 it’s used the same protocol but without the EDTA. A final irrigation of 2.0 mL 5,25% NaOCl for 3m was performed. Root filling was performed with Thermafil-obturators (Dentsply Tulsa, Tulsa, OK) with TopSeal (Dentsply, Maillefer) mixed with 0.1 wt% alizarin to evaluate the penetration depth of the sealer into tubules with confocal microscope (Leica, Wetzlar, Germany). Microleakage i.e. the volume of a calcein solution infiltrated into the root canal and tubules were evaluated using a digital fluid flow-meter and a confocal microscope. Results: Confocal microscopy showed a penetration of the sealer into tubules in group 1 of approx. 370 μm at 3 mm from the apex and 630 μm at 5 mm while in group 2 of approx. 22 μm at 3 mm and 37 μm at 5 mm from the apex. The volume of the infiltrated fluid was 0.353 x 10-4 mm3 for group 1 and 0.397 x 10-4 mm3 for group 2. The data of calcein penetration into the root canal were in agreement with the fluid filtration results. Conclusion: A correlation seems to be present between sealer penetration into dentinal tubules and sealability of Thermafil-obturators and TopSeal in root canal shaped with WaveOne Primary file.
2013
92
Gandolfi, Mg; Generali, Luigi; Ferri, A; Pelliccioni, Ga; Consolo, Ugo; Prati, C.
Correlation between Microleakage and Tubules Penetration of an Endodontic Sealer / Gandolfi, Mg; Generali, Luigi; Ferri, A; Pelliccioni, Ga; Consolo, Ugo; Prati, C.. - In: JOURNAL OF DENTAL RESEARCH. - ISSN 0022-0345. - ELETTRONICO. - 92:(2013). (Intervento presentato al convegno Annual Meeting of the IADR Continental European Division (CED) tenutosi a Firenze nel 4-7 settembre 2013).
File in questo prodotto:
File Dimensione Formato  
Paper180543.pdf

Open access

Tipologia: Abstract
Dimensione 62.21 kB
Formato Adobe PDF
62.21 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1065348
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact