This paper proposes a solution for reducing the ground leakage current in transformerless single-phase gridconnected photovoltaic converters. This is obtained with the introduction of an active common-mode filter able to compensate for variations of the output common-mode voltage of the power converter. The active common-mode filter is applied to a widespread and efficient full-bridge driven by a three-level pulse width modulation, allowing the power converter to operate with low ground leakage current and with an arbitrary power factor. After showing the desired voltage waveform for common-mode voltage compensation, this paper presents the design guidelines for the needed additional magnetic component together with the power loss considerations for all the devices added for the proposed solution. Experimental results show the performance of the proposed solution in terms of ground leakage current reduction, effectiveness of dead-time compensation, total harmonic distortion of the injected grid current, and power losses.

Active Common-Mode Filter for Ground Leakage Current Reduction in Grid-Connected PV Converters Operating With Arbitrary Power Factor / Barater, D.; Buticchi, G.; Lorenzani, Emilio; Concari, C.. - In: IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS. - ISSN 0278-0046. - STAMPA. - 61:8(2014), pp. 3940-3950. [10.1109/TIE.2013.2284160]

Active Common-Mode Filter for Ground Leakage Current Reduction in Grid-Connected PV Converters Operating With Arbitrary Power Factor

D. Barater;LORENZANI, EMILIO;
2014

Abstract

This paper proposes a solution for reducing the ground leakage current in transformerless single-phase gridconnected photovoltaic converters. This is obtained with the introduction of an active common-mode filter able to compensate for variations of the output common-mode voltage of the power converter. The active common-mode filter is applied to a widespread and efficient full-bridge driven by a three-level pulse width modulation, allowing the power converter to operate with low ground leakage current and with an arbitrary power factor. After showing the desired voltage waveform for common-mode voltage compensation, this paper presents the design guidelines for the needed additional magnetic component together with the power loss considerations for all the devices added for the proposed solution. Experimental results show the performance of the proposed solution in terms of ground leakage current reduction, effectiveness of dead-time compensation, total harmonic distortion of the injected grid current, and power losses.
2014
61
8
3940
3950
Active Common-Mode Filter for Ground Leakage Current Reduction in Grid-Connected PV Converters Operating With Arbitrary Power Factor / Barater, D.; Buticchi, G.; Lorenzani, Emilio; Concari, C.. - In: IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS. - ISSN 0278-0046. - STAMPA. - 61:8(2014), pp. 3940-3950. [10.1109/TIE.2013.2284160]
Barater, D.; Buticchi, G.; Lorenzani, Emilio; Concari, C.
File in questo prodotto:
File Dimensione Formato  
Active Common-Mode Filter for Ground Leakage Current Reduction.pdf

Accesso riservato

Descrizione: Articolo principale
Tipologia: Versione pubblicata dall'editore
Dimensione 1.3 MB
Formato Adobe PDF
1.3 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1004548
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 78
  • ???jsp.display-item.citation.isi??? 68
social impact