An investigation has been made into the behaviour of high-purity silicon (HP-Si) during the fabrication of microstrip detectors. The resistivity of the silicon used is 3 k-OMEGA cm. The investigation is centred on standard bipolar processes based on ion implantation. It is found that, comparing the processes used, the best diode characteristics are achieved when a heat treatment at 600-degrees-C is used after the ion-implantation step, whereas the worst results from an implantation and a 900-degrees-C heat treatment. Thus it is shown that if integration of the electronic circuitry and the detector on a single chip is required, then the high-temperature heat treatments must be done before the ion-implantation step needed for detector fabrication.

Processing high-quality silicon for microstrip detectors / Nava, Filippo; Ottaviani, Giampiero; Tonini, Rita; Frabboni, Stefano; A., Alberigi Quaranta; P., Cantoni; P. L., Frabetti; L., Stagni; G., Queirolo; P. F., Manfredi. - In: SENSORS AND ACTUATORS. A, PHYSICAL. - ISSN 0924-4247. - STAMPA. - 32:(1992), pp. 366-371. [10.1016/0924-4247(92)80014-T]

Processing high-quality silicon for microstrip detectors

NAVA, Filippo;OTTAVIANI, Giampiero;TONINI, Rita;FRABBONI, Stefano;
1992

Abstract

An investigation has been made into the behaviour of high-purity silicon (HP-Si) during the fabrication of microstrip detectors. The resistivity of the silicon used is 3 k-OMEGA cm. The investigation is centred on standard bipolar processes based on ion implantation. It is found that, comparing the processes used, the best diode characteristics are achieved when a heat treatment at 600-degrees-C is used after the ion-implantation step, whereas the worst results from an implantation and a 900-degrees-C heat treatment. Thus it is shown that if integration of the electronic circuitry and the detector on a single chip is required, then the high-temperature heat treatments must be done before the ion-implantation step needed for detector fabrication.
1992
32
366
371
Processing high-quality silicon for microstrip detectors / Nava, Filippo; Ottaviani, Giampiero; Tonini, Rita; Frabboni, Stefano; A., Alberigi Quaranta; P., Cantoni; P. L., Frabetti; L., Stagni; G., Queirolo; P. F., Manfredi. - In: SENSORS AND ACTUATORS. A, PHYSICAL. - ISSN 0924-4247. - STAMPA. - 32:(1992), pp. 366-371. [10.1016/0924-4247(92)80014-T]
Nava, Filippo; Ottaviani, Giampiero; Tonini, Rita; Frabboni, Stefano; A., Alberigi Quaranta; P., Cantoni; P. L., Frabetti; L., Stagni; G., Queirolo; P. F., Manfredi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/744089
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact