Sixteen patients (15 males, aged 48-70) affected by liver cirrhosis and oesophageal varices were subjected to duplex-Doppler ultrasonographic study (DDUS). Four patients (three with a portal thrombosis and one with a hepatofugal portal flow) were excluded from the subsequent pharmacological test. The twelve remaining patients took part in a double blind cross-over study that evaluated the variations of heart rate (HR), mean systemic arterial pressure (SAP), portal vein diameter (PVD), maximal and mean portal flow velocity (PFV) after the administration of either 40 mg of propranolol or placebo per os, on two consecutive days. Propranolol caused no significant variation in mean SAP and in PVD, whereas it reduced the HR from 67.7 +/- 8.0 to 58.4 +/- 7.0 beats/min (mean +/- s.d.; P less than 0.001); the maxPFV dropped from 18.2 +/- 5.4 to 14.0 +/- 3.7 cm/s (P less than 0.001) and the meanPFV dropped from 15.3 +/- 4.1 to 13.2 +/- 3.1 cm/s (P less than 0.005). No significant variation was observed with placebo. After propranolol administration eight patients exhibited a significant maxPFV decrease, whereas the other four patients exhibited only a drop in HR, suggesting either drug inefficacy, inappropriate dosage or inadequate duration of treatment. DDUS is the only non-invasive method for the examination of the portal vein system.(ABSTRACT TRUNCATED AT 250 WORDS)

Duplex-Doppler ultrasonography in the evaluation of cirrhotic patients with portal hypertension and in the analysis of their response to drugs / G., Cioni; P., D'Alimonte; F., Zerbinati; Ventura, Paolo; A., Cristani; A., Vignoli; R., Romagnoli; E., Ventura. - In: JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY. - ISSN 0815-9319. - STAMPA. - 7:(1992), pp. 388-392.

Duplex-Doppler ultrasonography in the evaluation of cirrhotic patients with portal hypertension and in the analysis of their response to drugs

VENTURA, Paolo;
1992

Abstract

Sixteen patients (15 males, aged 48-70) affected by liver cirrhosis and oesophageal varices were subjected to duplex-Doppler ultrasonographic study (DDUS). Four patients (three with a portal thrombosis and one with a hepatofugal portal flow) were excluded from the subsequent pharmacological test. The twelve remaining patients took part in a double blind cross-over study that evaluated the variations of heart rate (HR), mean systemic arterial pressure (SAP), portal vein diameter (PVD), maximal and mean portal flow velocity (PFV) after the administration of either 40 mg of propranolol or placebo per os, on two consecutive days. Propranolol caused no significant variation in mean SAP and in PVD, whereas it reduced the HR from 67.7 +/- 8.0 to 58.4 +/- 7.0 beats/min (mean +/- s.d.; P less than 0.001); the maxPFV dropped from 18.2 +/- 5.4 to 14.0 +/- 3.7 cm/s (P less than 0.001) and the meanPFV dropped from 15.3 +/- 4.1 to 13.2 +/- 3.1 cm/s (P less than 0.005). No significant variation was observed with placebo. After propranolol administration eight patients exhibited a significant maxPFV decrease, whereas the other four patients exhibited only a drop in HR, suggesting either drug inefficacy, inappropriate dosage or inadequate duration of treatment. DDUS is the only non-invasive method for the examination of the portal vein system.(ABSTRACT TRUNCATED AT 250 WORDS)
1992
7
388
392
Duplex-Doppler ultrasonography in the evaluation of cirrhotic patients with portal hypertension and in the analysis of their response to drugs / G., Cioni; P., D'Alimonte; F., Zerbinati; Ventura, Paolo; A., Cristani; A., Vignoli; R., Romagnoli; E., Ventura. - In: JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY. - ISSN 0815-9319. - STAMPA. - 7:(1992), pp. 388-392.
G., Cioni; P., D'Alimonte; F., Zerbinati; Ventura, Paolo; A., Cristani; A., Vignoli; R., Romagnoli; E., Ventura
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/617158
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 21
social impact