Inter and intra-observer agreement in classifying the presence of gallstones by ultrasonographic images according to established criteria was studied. A film recording of 50 routine ultrasonographic examinations of the gallbladder was read by each of the 46 observers who participated in the Multicenter Italian Study on Epidemiology of Cholelithiasis (M.I.COL.). The overall Kappa score for inter-observer agreement was 0.649, while intra-observer agreement was "good" or "excellent" (Kappa scores greater than 0.60) in 75% of the observers. No statistical difference for inter-observer agreement between "novices" and "expert" echographers was found in the overall Kappa statistic or in category-specific Kappa scores (gallstone, no gallstone, doubtful and inconclusive examinations) The present study suggests that the development of explicit criteria by a group of trained echographers does not eliminate inter- and intra-observer disagreement in categorizing subjects for gallbladder stones.

Inter and intra-observer variation in ultrasonographic detection of gallstones: the Multicenter Italian Study on Epidemiology of Cholelithiasis (M.I.COL.) / Festi, D; Lalloni, L; Taroni, F; Barbara, L; Menotti, A; Ricci, G; Loria, Paola; GROUP SEE APPENDIX, M. I. C. O. L.. - In: EUROPEAN JOURNAL OF EPIDEMIOLOGY. - ISSN 0393-2990. - ELETTRONICO. - 5:(1989), pp. 51-57.

Inter and intra-observer variation in ultrasonographic detection of gallstones: the Multicenter Italian Study on Epidemiology of Cholelithiasis (M.I.COL.)

LORIA, Paola;
1989

Abstract

Inter and intra-observer agreement in classifying the presence of gallstones by ultrasonographic images according to established criteria was studied. A film recording of 50 routine ultrasonographic examinations of the gallbladder was read by each of the 46 observers who participated in the Multicenter Italian Study on Epidemiology of Cholelithiasis (M.I.COL.). The overall Kappa score for inter-observer agreement was 0.649, while intra-observer agreement was "good" or "excellent" (Kappa scores greater than 0.60) in 75% of the observers. No statistical difference for inter-observer agreement between "novices" and "expert" echographers was found in the overall Kappa statistic or in category-specific Kappa scores (gallstone, no gallstone, doubtful and inconclusive examinations) The present study suggests that the development of explicit criteria by a group of trained echographers does not eliminate inter- and intra-observer disagreement in categorizing subjects for gallbladder stones.
1989
5
51
57
Inter and intra-observer variation in ultrasonographic detection of gallstones: the Multicenter Italian Study on Epidemiology of Cholelithiasis (M.I.COL.) / Festi, D; Lalloni, L; Taroni, F; Barbara, L; Menotti, A; Ricci, G; Loria, Paola; GROUP SEE APPENDIX, M. I. C. O. L.. - In: EUROPEAN JOURNAL OF EPIDEMIOLOGY. - ISSN 0393-2990. - ELETTRONICO. - 5:(1989), pp. 51-57.
Festi, D; Lalloni, L; Taroni, F; Barbara, L; Menotti, A; Ricci, G; Loria, Paola; GROUP SEE APPENDIX, M. I. C. O. L.
File in questo prodotto:
File Dimensione Formato  
Festi Eur J Epidemiol 1989.pdf

Solo gestori archivio

Tipologia: Versione pubblicata dall'editore
Dimensione 531.2 kB
Formato Adobe PDF
531.2 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/609471
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 21
social impact