Distortion product otoacoustic emissions (DPOAE) can be used to study cochlear function in an objective and non-invasive manner. One practical and essential aspect of any investigating measure is the consistency of its results upon repeated testing of the same individual/animal (i.e., its test/retest repeatability). The goal of the present work is to propose two indices to quantitatively assess the repeatability of DPOAE in laboratory animals. The methodology is here illustrated using two data sets which consist of DPOAE subsequently collected from Sprague-Dawley rats. The results of these experiments showed that the proposed indices are capable of estimating both the repeatability of the true emission level and the inconsistencies associated with measurement error. These indices could be a significantly useful tool to identify real and even small changes in the cochlear function exerted by potential ototoxic agents.

Quantitative indexes for the assessment of the repeatability of distortion product otoacoustic emissions in laboratory animals / M., Parazzini; P., Galloni; Brazzale, Alessandra Rosalba; G., Tognola; C., Marino; P., Ravazzani. - In: IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING. - ISSN 0018-9294. - STAMPA. - 53:8(2006), pp. 1550-1556. [10.1109/TBME.2006.877804]

Quantitative indexes for the assessment of the repeatability of distortion product otoacoustic emissions in laboratory animals

BRAZZALE, Alessandra Rosalba;
2006

Abstract

Distortion product otoacoustic emissions (DPOAE) can be used to study cochlear function in an objective and non-invasive manner. One practical and essential aspect of any investigating measure is the consistency of its results upon repeated testing of the same individual/animal (i.e., its test/retest repeatability). The goal of the present work is to propose two indices to quantitatively assess the repeatability of DPOAE in laboratory animals. The methodology is here illustrated using two data sets which consist of DPOAE subsequently collected from Sprague-Dawley rats. The results of these experiments showed that the proposed indices are capable of estimating both the repeatability of the true emission level and the inconsistencies associated with measurement error. These indices could be a significantly useful tool to identify real and even small changes in the cochlear function exerted by potential ototoxic agents.
2006
53
8
1550
1556
Quantitative indexes for the assessment of the repeatability of distortion product otoacoustic emissions in laboratory animals / M., Parazzini; P., Galloni; Brazzale, Alessandra Rosalba; G., Tognola; C., Marino; P., Ravazzani. - In: IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING. - ISSN 0018-9294. - STAMPA. - 53:8(2006), pp. 1550-1556. [10.1109/TBME.2006.877804]
M., Parazzini; P., Galloni; Brazzale, Alessandra Rosalba; G., Tognola; C., Marino; P., Ravazzani
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/607778
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact