A new optical instrument for `in vivo' analysis of ocular tissue is presented. The instrument is based on the well know dynamic light scattering technique. Using optimal beam shaping the analysis can be achieved in the cornea and in the anterior chamber as well as in the lens and in the vitreous with high spatial resolution and sensitivity. In order to obtain high beam quality, to provide modularity and galvanic insulation of the instrument, monomode optical fibers are used to guide the excitation and the scattered light. Following a description of the instrument, preliminary `in-vivo' measures are discussed in order to asses the performance of the instrument in ophthalmology diagnostics

A non invasive instrument for in vivo dynamic laser light scattering measurement in the human eye / Rovati, Luigi; Ii, Fankhauser; J., Ricka. - STAMPA. - 2:(1995), pp. 1621-1622. (Intervento presentato al convegno IEEE 17th Annual Conference Engineering in Medicine and Biology Society tenutosi a Montreal nel 1995-Sep).

A non invasive instrument for in vivo dynamic laser light scattering measurement in the human eye

ROVATI, Luigi;
1995

Abstract

A new optical instrument for `in vivo' analysis of ocular tissue is presented. The instrument is based on the well know dynamic light scattering technique. Using optimal beam shaping the analysis can be achieved in the cornea and in the anterior chamber as well as in the lens and in the vitreous with high spatial resolution and sensitivity. In order to obtain high beam quality, to provide modularity and galvanic insulation of the instrument, monomode optical fibers are used to guide the excitation and the scattered light. Following a description of the instrument, preliminary `in-vivo' measures are discussed in order to asses the performance of the instrument in ophthalmology diagnostics
1995
IEEE 17th Annual Conference Engineering in Medicine and Biology Society
Montreal
1995-Sep
2
1621
1622
Rovati, Luigi; Ii, Fankhauser; J., Ricka
A non invasive instrument for in vivo dynamic laser light scattering measurement in the human eye / Rovati, Luigi; Ii, Fankhauser; J., Ricka. - STAMPA. - 2:(1995), pp. 1621-1622. (Intervento presentato al convegno IEEE 17th Annual Conference Engineering in Medicine and Biology Society tenutosi a Montreal nel 1995-Sep).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/595039
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact