In this paper a novel low-coherence sensor based on a self- mixing super-luminescent diode (SM-SLD) is described. A commercial low-cost super-luminescent diodes (SLD) driven at constant current is used as low-coherence source. In the same case of the SLD there is a photodiode generally used to monitor the optical power at the emitting junction back-face. In the SM-SLD technique, this photodiode is exploited to detect the interference signal. Hence, the interference signal is optically amplified by the high-gain active medium. The sensor has been properly designed to work in industrial environments and is suitable for measurement of semitransparent slabs thickness, i.e. glass, Plexiglas, polyethylene, etc. Measurements carried out on glass slabs show a measuring range of 15 mm and a linearity error and stability of 1.3 micrometer and 1.6 micrometer respectively.

Design and performance of a low-coherence sensor for industrial applications based on a self-mixing superluminescent diode / Rovati, Luigi; Docchio, F.. - STAMPA. - 3823:(1999), pp. 164-167. (Intervento presentato al convegno SPIE Europe tenutosi a Munich nel Giugno).

Design and performance of a low-coherence sensor for industrial applications based on a self-mixing superluminescent diode

ROVATI, Luigi;
1999

Abstract

In this paper a novel low-coherence sensor based on a self- mixing super-luminescent diode (SM-SLD) is described. A commercial low-cost super-luminescent diodes (SLD) driven at constant current is used as low-coherence source. In the same case of the SLD there is a photodiode generally used to monitor the optical power at the emitting junction back-face. In the SM-SLD technique, this photodiode is exploited to detect the interference signal. Hence, the interference signal is optically amplified by the high-gain active medium. The sensor has been properly designed to work in industrial environments and is suitable for measurement of semitransparent slabs thickness, i.e. glass, Plexiglas, polyethylene, etc. Measurements carried out on glass slabs show a measuring range of 15 mm and a linearity error and stability of 1.3 micrometer and 1.6 micrometer respectively.
1999
SPIE Europe
Munich
Giugno
3823
164
167
Rovati, Luigi; Docchio, F.
Design and performance of a low-coherence sensor for industrial applications based on a self-mixing superluminescent diode / Rovati, Luigi; Docchio, F.. - STAMPA. - 3823:(1999), pp. 164-167. (Intervento presentato al convegno SPIE Europe tenutosi a Munich nel Giugno).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/466683
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact