Large angle convergent beam electron diffraction (LACBED) technique has been applied to <110> TEM cross section of silicon samples implanted with 2x1016 cm-2 He ions at an energy of 20 KeV in order to evaluate the stress/strain field in the implanted layer. The stress/strain field depends on the mismatch between the lattice of the silicon substrate and the one of the defective layer which contains clusters of point defects and small He bubbles. Lattice mismatch causes changes in the spacing and inclination of diffraction planes producing a shift and a rotation of diffraction intensity lines (Bragg contours (BC)) visible in LACBED patterns. In particular, when the electron beam is parallel to the rotation axis, the BC simply rotate. This is the case of mismatches observed with (333) BC when the electron beam is incident on the sample along a direction close to <110> zone axis. Measurements show a peak of the stress/strain field (intensity 1.5 GPa) at a depth close to the helium projected range, where small bubbles occasionally form aggregate oriented along <011> direction.

Large angle convergent beam electron diffraction strain measurements in high dose helium implanted silicon / Gambetta, Francesca; Frabboni, Stefano; Tonini, Rita; Corni, Federico. - In: MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY. - ISSN 0921-5107. - STAMPA. - 71:(2000), pp. 87-91. [10.1016/S0921-5107(99)00354-2]

Large angle convergent beam electron diffraction strain measurements in high dose helium implanted silicon

GAMBETTA, Francesca;FRABBONI, Stefano;TONINI, Rita;CORNI, Federico
2000

Abstract

Large angle convergent beam electron diffraction (LACBED) technique has been applied to <110> TEM cross section of silicon samples implanted with 2x1016 cm-2 He ions at an energy of 20 KeV in order to evaluate the stress/strain field in the implanted layer. The stress/strain field depends on the mismatch between the lattice of the silicon substrate and the one of the defective layer which contains clusters of point defects and small He bubbles. Lattice mismatch causes changes in the spacing and inclination of diffraction planes producing a shift and a rotation of diffraction intensity lines (Bragg contours (BC)) visible in LACBED patterns. In particular, when the electron beam is parallel to the rotation axis, the BC simply rotate. This is the case of mismatches observed with (333) BC when the electron beam is incident on the sample along a direction close to <110> zone axis. Measurements show a peak of the stress/strain field (intensity 1.5 GPa) at a depth close to the helium projected range, where small bubbles occasionally form aggregate oriented along <011> direction.
2000
71
87
91
Large angle convergent beam electron diffraction strain measurements in high dose helium implanted silicon / Gambetta, Francesca; Frabboni, Stefano; Tonini, Rita; Corni, Federico. - In: MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY. - ISSN 0921-5107. - STAMPA. - 71:(2000), pp. 87-91. [10.1016/S0921-5107(99)00354-2]
Gambetta, Francesca; Frabboni, Stefano; Tonini, Rita; Corni, Federico
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/450525
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact